in 
   



Preview   - English
Cover Image
 

AS/NZS 3001:2001
Electrical installations - Relocatable premises (including caravans and tents) and their site installations


Be notified when this Standard is updated or amended - Add to StandardsWatch

General Product Information

Document Type Standard
Status AvailableSuperseded
Publisher:    Standards Australia
Committee EL-001
Superseded By:
AS/NZS 3001:2008
Supersedes:
AS 3001-1990
AS 3005-1982
DR 01026 CP



LexConnect

This Standard is referenced in Legislation – Access LexConnect here

Available Products          My Location  :
Product availability, format and price varies from country to country. Please Login/register.
Order   Format Device Compatibility Price [USD]
Preferred Currency

   
Not Available*
PDF (Networkable/Copy/Paste)
PC/Mobile  
Published:   07 Dec 2001  
ISBN: 0-7337-4162-2
Pages: 26
     info icon.jpg 3 concurrent users. Copy/Paste allowed. Print 3 Copies. More info

Not Available*
PDF (Networkable)
PC/Mobile  
Published:   07 Dec 2001  
ISBN: 0-7337-4162-2
Pages: 26
     info icon.jpg 3 concurrent users. No Copy/Paste. Print 3 copies. More info

Not Available*
PDF (Copy/Paste)
PC/Mobile  
Published:   07 Dec 2001  
ISBN: 0-7337-4162-2
Pages: 26
     info icon.jpg No sharing. Copy/Paste for internal use allowed. Print once. More info


Add To Cart

PDF (Personal Use)
PC/Mobile  
$93.63
Published:   07 Dec 2001  
ISBN: 0-7337-4162-2
Pages: 26
     info icon.jpg No Sharing. No Copy/Paste. Print once. More info


Add To Cart

Hardcopy
--  
$93.63
Published:   07 Dec 2001  
Delivery Time:   up to 10 days
ISBN: 0-7337-4162-2
Pages: 26

*Some products are not available for sale in your country due to licensing restrictions imposed on us by the publishers.


Table of Contents

Skip Navigation Links.

Abstract

Specifies requirements, in addition to those of AS/NZS 3000:2000, for electrical installations in relocatable premises, including caravans and tents, and in caravan parks and camping areas.

Scope

This Standard sets out requirements for electrical installations associated with relocatable premises intended for connection to low-voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).
It includes requirements for the internal electrical installation of applicable relocatable premises and for certain types of electrical installations intended to supply electrical power to those premises. Such installations include caravan parks and camping areas with powered sites but excludes fairgrounds and temporary camping sites, which are subject to the requirements of AS/NZS 3002, and construction and demolition sites, which are subject to the requirements of AS/NZS 3012.
Relocatable premises within the coverage of this Standard include the following:
(a) Registrable vehicles offering accommodation, including caravans, camper vans, motor homes, camper trailers and livestock or car transporters with accommodation included.
(b) In New Zealand, other registrable premises including food and drink vending vans and trailers, mobile x-ray caravans, mobile blood banks, walk-through educational display caravans and trailers, mobile classrooms, television outside broadcast vans. (c) Non-registrable relocatable premises including relocatable homes, transportable huts, tents for accommodation, and rigid and non-rigid annexes to premises referred to in (a) and (b).
(d) Temporary site offices, cloakrooms, meeting offices, dormitories, canteens, toilets or other facilities provided on construction and demolition sites.
(e) In New Zealand, registrable display units not requiring occupation, e.g. mobile electronic score boards and advertising signs, mobile traffic information signs This Standard does not apply to the following electrical installations: (i) Relocatable premises with a permanently connected electricity supply and not intended to be relocated, e.g. tramcars, buses or caravans rendered immobile, transportable sheds.
These are subject to the requirements of AS/NZS 3000.
(ii) Registrable vehicles with fixed wiring that are amusement rides or concessions. These are subject to the requirements of AS 3533.
(iii) In Australia other registrable premises including food and drink vending vans and trailers, mobile x-ray caravans, mobile blood banks, walk-through educational display caravans and trailers, mobile classrooms, television outside broadcast vans.
NOTE: It is intended that the inclusion of at least some of these items in the scope for Australia will be investigated in the near future.
(iv) Relocatable premises, without fixed wiring, for provision of entertainment. e.g. circus and carnival tents, temporary vending stalls.
These are subject to the requirements of AS/NZS 3002.
(v) In Australia, registrable display units not requiring occupation, e.g. mobile electronic score boards and advertising signs, mobile traffic information signs.

Application

Electrical installations of relocatable premises and sites shall be carried out in accordance with AS/NZS 3000 except as varied herein and with the additional requirements of this Standard.

History

First published as AS 3001-1959.
Second edition 1966.
Third edition 1977.
Fourth edition 1981.
AS 3005 first published 1982.
Fifth edition AS 3001-1985.
Sixth edition 1990.
AS 3001-1990 and AS 3005-1982 jointly revised, amalgamated and redesignated as AS/NZS 3001:2001.