Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1170.4 SUPP 1-1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads - Commentary (Supplement to AS 1170.4-1993)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

14-06-2023

Language(s)

English

Published date

16-08-1993

Preview

1 - AS 1170.4 Supp1-1993 MINIMUM DESIGN LOADS ON STRUCTURES - EARTHQUAKE LOADS-COMMENTARY
4 - PREFACE
4 - ACKNOWLEDGEMENT
5 - CONTENTS
7 - SECTION C1 SCOPE AND GENERAL
7 - C1.1 SCOPE
7 - C1.2 REFERENCED DOCUMENTS
7 - C1.3 DEFINITIONS
7 - C1.6 EARTHQUAKE LOAD COMBINATIONS
8 - SECTION C2 GENERAL REQUIREMENTS
8 - C2.3 ACCELERATION COEFFICIENT
11 - C2.4 SITE FACTOR
11 - C2.5 IMPORTANCE FACTOR
11 - C2.6 EARTHQUAKE DESIGN CATEGORY
11 - C2.7 REQUIREMENTS FOR GENERAL STRUCTURES
11 - C2.7.1 General
12 - C2.7.2 General structures of earthquake Design Category A
12 - C2.7.3 General structures of earthquake Design Category B
12 - C2.7.4 General structures of earthquake Design Category C
12 - C2.7.5 General structures of earthquake Design Category D
12 - C2.7.6 General structures of earthquake Design Category E
13 - C2.8 STRUCTURAL SYSTEMS OF BUILDINGS
15 - C2.9 CONFIGURATION
16 - C2.10 DEFLECTION AND DRIFT LIMITS
17 - SECTION C3 DOMESTIC STRUCTURES
17 - C3.1 GENERAL
17 - C3.2 REQUIREMENTS FOR EARTHQUAKE DESIGN CATEGORIES
17 - C3.3 STRUCTURAL DETAILING REQUIREMENTS FOR DOMESTIC STRUCTURES
17 - C3.4 STATIC ANALYSIS FOR NON-DUCTILE DOMESTIC STRUCTURES OF EARTHQUAKE DESIGN CATEGORY H3
17 - C3.5 NON-STRUCTURAL COMPONENTS
18 - SECTION C4 STRUCTURAL DETAILING REQUIREMENTS FOR GENERAL STRUCTURES
18 - C4.1 GENERAL
18 - C4.2 STRUCTURAL DETAILING REQUIREMENTS FOR STRUCTURES OF EARTHQUAKE DESIGN CATEGORY A
18 - C4.3 STRUCTURAL DETAILING REQUIREMENTS FOR STRUCTURES OF EARTHQUAKE DESIGN CATEGORY B
18 - C4.3.2 Load paths, ties and continuity
18 - C4.3.3 Wall anchorage
18 - C4.4 STRUCTURAL DETAILING REQUIREMENTS FOR STRUCTURES OF EARTHQUAKE DESIGN CATEGORIES C, D AND E
18 - C4.4.2 Ties and continuity
18 - C4.4.6 Footing ties
19 - SECTION C5 REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS
19 - C5.1 GENERAL REQUIREMENTS
19 - C5.1.1 General
19 - C5.1.2 Forces on components
19 - C5.1.3 Interrelationship of components
19 - C5.1.4 Connections and attachments
20 - C5.2 REQUIREMENTS FOR ARCHITECTURAL COMPONENTS
20 - C5.2.1 Forces
20 - C5.2.2 Exterior wall panel attachment
20 - C5.2.3 Component deformation
21 - C5.2.4 Out-of-plane bending
21 - C5.3 REQUIREMENTS FOR MECHANICAL AND ELECTRICAL COMPONENTS
21 - C5.3.1 Forces
21 - C5.3.2 Ducts and piping distribution systems
21 - C5.4 AMPLIFICATION FACTOR
21 - C5.4.1 Attachment amplification factor
22 - C5.4.2 Height amplification factor
23 - SECTION C6 STATIC ANALYSIS
23 - C6.1 GENERAL
23 - C6.2 HORIZONTAL FORCES
23 - C6.2.1 General
23 - C6.2.2 Earthquake base shear
24 - C6.2.3 Earthquake design coefficient
24 - C6.2.4 Structure period
24 - C6.2.5 Gravity load
24 - C6.2.6 Structural response factor
25 - C6.3 VERTICAL DISTRIBUTION OF HORIZONTAL EARTHQUAKE FORCES
25 - C6.4 HORIZONTAL SHEAR DISTRIBUTION
25 - C6.5 TORSIONAL EFFECTS
26 - C6.6 STABILITY EFFECTS
27 - C6.7 DRIFT DETERMINATION AND P-DELTA EFFECTS
27 - C6.8 VERTICAL COMPONENTS OF GROUND MOTION
28 - SECTION C7 DYNAMIC ANALYSIS
28 - C7.1 GENERAL
29 - C7.2 EARTHQUAKE ACTIONS
30 - C7.3 MATHEMATICAL MODEL
32 - C7.4 ANALYSIS PROCEDURES
32 - C7.4.2 Response spectrum analysis
34 - C7.4.3 Time history analysis
36 - APPENDIX CE - STRUCTURAL ALTERATIONS
36 - CE1 INTRODUCTION
36 - CE2 DESIGN
37 - BIBLIOGRAPHY

The commentary provides background material for and guidance to the requirements of AS 1170.4, Earthquake loads.

The Standard considers loads on structures due to earthquake ground motion. The provisions are not intended to prevent damage due to surface rupture, landslip or liquefaction. Nor do they consider other secondary earthquake effects such as fire, loss of services, seiche or tsunami. They do not consider site-structure resonance, where the natural frequency of a site is the same as that of the structure. They do not consider pounding of adjacent structures moving out of phase in an earthquake. These aspects require consideration of issues other than 'loads' and therefore are inappropriate in a loading Standard.

Special structures require special consideration of their response characteristics and environment that is beyond the scope of these provisions. Special structures such as nuclear reactors and cyrogenic tanks, which may present a considerable hazard to the community in the event of their failure, are not covered by the Standard, nor are industrial facilities of high economic importance. In either event, such structures require consideration of strong earthquake motions of very low probability, regardless of location. Structures with unusual structural characteristics, or of novel design or construction, are not excluded by the Standard. However, the Standard may be of little assistance in the design of such structures since a structural response factor (Rf) may not have been assigned.

Bridges are not covered by the Standard but could be included with some additional requirements.

Agricultural buildings may be excluded from earthquake consideration because of the exceptionally low risk to life involved.

Alterations to existing structures are covered by these provisions (see Section 8) but the assessment, strengthening and repairs to existing structures are not covered. However, guidance and some information are included in Appendix E..

Committee
BD-006
DocumentType
Supplement (Main)
ISBN
0 7262 8298 7
Pages
32
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

First published as part of AS 2121-1979.Revised and redesignated in part as AS 1170.4 Supplement 1-1993. First published as part of AS 2121-1979. Revised and redesignated in part as AS 1170.4 Supplement 1-1993.

AS 1684.3-2010 Residential timber-framed construction Cyclonic areas
AS 1684.4-2010 Residential timber-framed construction Simplified - Non-Cyclonic Areas
AS/NZS 1576.1:2010 Scaffolding General requirements
AS 1684.2-2010 Residential timber-framed construction Non-cyclonic areas
AS 1725.3-2010 Chain link fabric fencing Tennis court fencing - Private/Residential (Reconfirmed 2020)
AS/NZS 5070.1:2008 Siting and operation of radiocommunications facilities General guidelines for fixed, mobile and broadcasting facilities including fixed location satellite earth stations independent of the operating frequency (Reconfirmed 2019)
AS 1445-2013 Hot-dipped zinc-coated, aluminium/zinc-coated or aluminium/zinc/magnesium-coated steel sheet - 76 mm pitch corrugated
AS 1210-2010 Pressure vessels (Reconfirmed 2021)
AS/NZS 4994.4:2018 Temporary edge protection Perimeter Protection Screens
AS 1228-2006 Pressure equipment - Boilers
AS 2159-2009 Piling - Design and installation
HB 867-2007 Supplementary information for design of farm structures
AS/NZS 2041.1:2011 Buried corrugated metal structures Design methods
AS 2941-2008 Fixed fire protection installations - Pumpset systems
SA HB 108-2013 Timber design handbook
AS 4773.2-2010 Masonry in small buildings - Construction
AS 2885.2-2007 Pipelines - Gas and liquid petroleum Welding
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 1725.4-2010 Chain link fabric fencing Cricket net fencing enclosures (Reconfirmed 2020)
AS 3700-2011 Masonry structures
AS 4773.1-2010 Masonry in small buildings - Design
AS 2941-2013 Fixed fire protection installations - Pumpset systems
AS/NZS 4509.1:2009 Stand-alone power systems Safety and installation (Reconfirmed 2017)
AS 2885.1-2007 Pipelines - Gas and liquid petroleum - Design and construction
AS 3533.1-2009 Amusement rides and devices Design and construction
AS 2316.1-2009 Artificial climbing structures and challenge courses Fixed and mobile artificial climbing and abseiling walls
AS/NZS 1596:2008 The storage and handling of LP Gas
AS 3600-2009 Concrete structures
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS 1725.1-2010 Chain link fabric fencing Security fences and gates - General requirements (Reconfirmed 2020)
AS/NZS 4284:2008 Testing of building facades
AS 1375-2013 Industrial fuel-fired appliances
AS 2304-2011 Water storage tanks for fire protection systems
AS 2885.1-2012 Pipelines - Gas and liquid petroleum Design and construction
AS/NZS 4509.2:2010 Stand-alone power systems System design (Reconfirmed 2017)
AS/NZS 1596:2014 The storage and handling of LP Gas
AS 4324.1:2017 Mobile equipment for continuous handling of bulk materials General requirements for the design of steel structures
AS 1725.5-2010 Chain link fabric fencing Sports ground fencing - General requirements (Reconfirmed 2020)

View more information
$99.73
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more