Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1979-1993

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Electric cables - Lifts - Flexible travelling
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Language(s)

English

Published date

01-01-1993

Preview

1 - AS 1979-1993 ELECTRIC CABLES - LIFTS - FLEXIBLE TRAVELLING
4 - PREFACE
4 - CONTENTS
5 - 1 SCOPE
5 - 2 REFERENCED DOCUMENTS
5 - 3 DEFINITIONS
5 - 3.1 Core (of a cable)
5 - 3.2 Direction of lay
5 - 3.3 Length of lay
5 - 3.4 Suspended length
5 - 3.5 Support member
5 - 3.6 Telecommunications circuit assembly
5 - 3.7 Voltage designation
5 - 3.8 Routine tests
5 - 3.9 Special tests
5 - 3.10 Type tests
6 - 4 CABLE CONSTRUCTION
6 - 5 CONDUCTORS
6 - 6 INSULATION (OTHER THAN FOR TELECOMMUNICATIONS CIRCUITS)
6 - 6.1 Material
6 - 6.2 Thickness
6 - 7 IDENTIFICATION OF CORES, CORE ASSEMBLIES AND TELECOMMUNICATION CIRCUIT ASSEMBLIES
6 - 7.1 Identification
6 - 7.2 Prohibited colours
6 - 8 SCREENED TELECOMMUNICATION CIRCUIT ASSEMBLIES
7 - 9 SUPPORT MEMBERS
7 - 9.1 Preformed high-tensile steel support members
7 - 9.2 Non-metallic support members
7 - 10 FILLERS AND BINDERS
7 - 11 TEXTILE BRAID OVER LAID-UP CORE ASSEMBLY
7 - 12 SHEATH
7 - 12.1 Material
7 - 12.2 Thickness
9 - 13 SUSPENDED LENGTHS
9 - 14 MARKING
9 - 14.1 Marking on cables
9 - 14.2 Marking of drums
9 - 15 TESTING OF CABLES
9 - 15.1 General
9 - 15.2 High voltage test on completed cable
9 - 15.3 Flexing test
12 - APPENDIX A - CALCULATION OF SUSPENDED LENGTHS FOR CABLES
12 - APPENDIX B - NATURAL LOOP TEST
13 - APPENDIX C - PURCHASING GUIDELINES

Specifies flexible travelling cables with copper conductors, in circular or flat configuration, intended for use in power, control, lighting, indicator, telecommunications or other similar circuits in electric lifts, at a voltage not exceeding 250/440 V or 250 volt.

This Standard applies to flexible travelling cables with copper conductors, with or without support members, in circular or flat configuration intended for use in power, control, lighting, indicator, telecommunications and other similar circuits in electric lifts at a voltage not exceeding 250/440 V or 250 V.NOTE: Purchasing guidelines are contained in Appendix C.

Committee
EL-003
DocumentType
Standard
ISBN
0 7262 7801 7
Pages
9
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

First published as AS C307-1952.Second edition 1965.Third edition 1972.Revised and redesignated AS 1979-1976.Second edition 1993. First published as AS C307-1952. Second edition 1965. Third edition 1972. Revised and redesignated AS 1979-1976. Second edition 1993.

AS 1125-1993 Conductors in insulated electric cables and flexible cords
AS 3191-1981 Approval and test specification for electric flexible cords (incorporating Corrigenda)

AS 1735.17-1995 Lifts, escalators and moving walks Lifts for people with limited mobility - Restricted use - Water-drive
AS 1735.14-1998 Lifts, escalators and moving walks Low-rise platforms for passengers
AS 1735.2-1993 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS/NZS 1735.18:2002 Lifts, escalators, and moving walks Passenger lifts for private residence - Automatically controlled
AS 1972-1991 Electric cables - Underground coal mines - Other than reeling and trailing cables
AS 1735.2-1997 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 1735.6(INT)-1996 Lifts, escalators and moving walks Moving walks
AS 1735.4-1986 SAA Lift Code Service lifts - Power-operated
AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
AS 1735.2-2001 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 1735.15-2002 Lifts, escalators, and moving walks Low-rise passenger lifts - Non-automatically controlled
AS 1735.5-1996 Lifts, escalators and moving walks - Escalators
AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
AS 1735.16-1993 Lifts, escalators and moving walks Lifts for persons with limited mobility - Restricted use - Automatically controlled
AS 1418.13-1996 Cranes (including hoists and winches) Building maintenance units
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
AS/NZS 1972:1996 Electric cables - Underground coal mines - Other than reeling and trailing
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)

View more information
$57.13
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more