1 - AS 3735 Supp1-2001 CONCRETE STRUCTURES FOR RETAINING LIQUIDS-COMMENTARY (SUPPLEMENT TO AS 3735-2001)
4 - PREFACE
5 - CONTENTS
6 - SECTION C1 SCOPE AND GENERAL
6 - C1.1 SCOPE
6 - C1.5 USE OF ALTERNATIVE MATERIALS OR METHODS
6 - C1.5.3 Ferrocement
6 - C1.6 DRAWINGS AND SPECIFICATIONS
7 - REFERENCES
8 - SECTION C2 LOADS, LOAD COMBINATIONS FOR STABILITY, STRENGTH AND SERVICEABILITY
8 - C2.1 GENERAL
8 - C2.2 LOADS AND OTHER ACTIONS
8 - C2.2.1 Temperature
11 - C2.2.2 Moisture variation
12 - C2.2 3 Earthquake
12 - C2.2.4 Other actions
13 - C2.3 STABILITY DESIGN
13 - C2.4 LOAD COMBINATIONS FOR SERVICEABILITY
14 - REFERENCES
15 - SECTION C3 DESIGN FOR SERVICEABILITY AND STRENGTH
15 - C3.1 GENERAL
15 - C3.2 REINFORCED CONCRETE
15 - C3.2.1 General
17 - C3.2.2 Minimum reinforcement ratio
18 - C3.2.3 Limiting steel stresses for serviceability
19 - C3.2.4 Limiting concrete thickness
20 - C3.3 PRESTRESSED CONCRETE
20 - C3.3.1 General
20 - C3.3.2 Analysis
22 - C3.3.3 Limiting concrete stresses for serviceability
23 - REFERENCES
24 - SECTION C4 DESIGN FOR DURABILITY
24 - C4.1 GENERAL
25 - C4.2 EXPOSURE CLASSIFICATION
33 - C4.3 REQUIREMENTS FOR CONCRETE
35 - C4.4 REQUIREMENTS FOR COVER TO REINFORCING STEEL AND TENDONS
35 - C4.4.1 General
35 - C4.4.3 Cover for corrosion protection
36 - C4.4.4 Cover modifications for special circumstances
37 - C4.6 DURABILITY OF WATERSTOPS AND SEALANTS
37 - REFERENCES
39 - SECTION C5 MATERIALS AND CONSTRUCTION REQUIREMENTS
39 - C5.2 CONCRETE
39 - C5.2.2 Curing
39 - C5.3 REINFORCEMENT
39 - C5.3.1 Protective coating
40 - REFERENCES
41 - SECTION C6 JOINTS, WATERSTOPS, AND SEALANTS
41 - C6.1 JOINTS
41 - C6.1.1 Purpose
41 - C6.1.2 Non-movement
41 - C6.1.3 Movement
47 - C6.2 WATERSTOPS
48 - C6.3 JOINT FILLERS
48 - C6.4 SEALANTS
50 - C6.5 CONTAMINATION OF WATER
50 - REFERENCES
51 - SECTION C7 TESTING
51 - C7.1 GENERAL
52 - APPENDIX A - CYLINDRICAL TANK THERMAL STRESSES
52 - A1 GENERAL
52 - A2 SHAPE FACTOR
52 - A3 THERMAL STRESS COEFFICIENT
52 - A4 TEMPERATURE CHANGE
52 - A4.1 Average
52 - A4.2 Differential
53 - A4.3 Total
53 - A5 THERMAL WALL STRESS

Provides commentary and additional information to AS 3735, Concrete structures retaining liquids. Includes tables and drawings to assist in the usage of that Standard.

A lower concrete strength limit of 20 MPa has been imposed, as strength grades less than this are not considered suitable for structures.An upper concrete strength limit of 50 MPa has been adopted, because much of the research on which the Standard is based involved concrete strengths at or below this value. Nevertheless, higher strength concretes are being used in Australia and overseas (Refs 1 and 2). The Standard may be applied to such concretes, provided that the physical properties appropriate to them are used in design.The Standard also limits the use of lightweight aggregate in structural concrete. Most Australian structural concretes employ only lightweight coarse aggregate, resulting in concrete with a surface-dry density that is seldom less than 1800 kg/m3.In the preparation of a Standard such as this, a certain level of knowledge and competence of the majority of users has been assumed. As indicated by the Note to Clause 1.1, it was assumed that the predominant users of this Standard would be professionally qualified civil engineers experienced in the design of concrete structures for retaining liquids, or equally qualified but less experienced persons working under their guidance. It is therefore intended that the Standard be applied and interpreted primarily by such persons.

Committee
CE-022
DocumentType
Supplement (Main)
ISBN
0 7337 3715 3
Pages
58
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS 3735 Supplement 1-1991.Second edition 2001. Originated as AS 3735 Supp1-1991. Second edition 2001.

AS 3958.1-2007 Ceramic tiles Guide to the installation of ceramic tiles
AS 2159-2009 Piling - Design and installation
HB 230-2008 Rainwater Tank Design and Installation Handbook
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 5100.5:2017 Bridge design Concrete

View more information
$135.16
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more