Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 1365-1:2012

Current
Current

The latest, up-to-date edition.

Fire resistance tests for loadbearing elements Walls
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-05-2013

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Bibliography

Describes a method of testing the fire resistance of loadbearing walls.

This European Standard specifies a method of testing the fire resistance of loadbearing walls. It is applicable to both internal and external walls. The fire resistance of external walls can be determined under internal or external exposure conditions.

The fire resistance performance of loadbearing walls is normally evaluated without perforations such as doors, glazing or fire resistant ducts. If it can be demonstrated that the design of the opening is such that load is not transmitted to the perforation, then the perforation need not be tested in the loaded condition. If perforations are to be included, the effects of these will need to be separately established.

This test method is not applicable to non-separating loadbearing walls which, in short widths, can be tested as columns to EN 1365-4.

This European Standard is used in conjunction with EN 1363-1.

Committee
FSH/22/-/7
DevelopmentNote
Supersedes 94/306104 DC. (09/2005)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

14/30295812 DC : 0 BS 8458 - FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - CODE OF PRACTICE FOR DESIGN AND INSTALLATION
07/30147204 DC : 0 BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS
04/30104952 DC : DRAFT MARCH 2004 BS 5502-23 - BUILDING AND STRUCTURES FOR AGRICULTURE - PART 23 - FIRE PRECAUTIONS - CODE OF PRACTICE
BS 5502-23:2004 Buildings and structures for agriculture Fire precautions. Code of practice
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs
BS DD8458-1(2010) : 2010 FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
PD 7974-3:2003 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3)
BS 8458:2015 Fixed fire protection systems. Residential and domestic watermist systems. Code of practice for design and installation

ISO 13943:2017 Fire safety — Vocabulary
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1365-4:1999 Fire resistance tests for loadbearing elements - Part 4: Columns
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more