Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 3001:2008

Current

Current

The latest, up-to-date edition.

Electrical installations - Transportable structures and vehicles including their site supplies

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

05-12-2008

Preview

This Standard sets out requirements for electrical installations associated with transportable structures and vehicles intended for connection to low-voltage a.c. supply systems (i.e. exceeding 50V a.c. but not exceeding 1000V a.c.). For the purposes of this Standard the term transportable structure includes vehicles and structures with or without wheels that are capable of being readily moved from one site to another either under their own motive power or otherwise..

This Standard sets out the requirements for electrical installations associated with transportable structures and vehicles that are intended for connection to low-voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).For the purposes of this Standard the term ‘transportable structure’ includes both vehicles and structures with or without wheels that can readily be moved from one site to another either under their own motive power or by some other means.This Standard includes additional requirements to those detailed in AS/NZS 3000 for the internal electrical wiring of transportable structures and for any electrical installations intended to provide a low voltage supply for transportable structures by a socket-outlet and plug arrangement that can be connected by unskilled persons. Such installations include those in caravan parks and camping areas with powered sites but exclude those in fairgrounds and temporary camping sites, which are subject to the requirements of AS/NZS 3002, and those in construction and demolition sites, which are subject to the requirements of AS/NZS 3012.Transportable structures within the scope of this Standard include the following:(a) Vehicles offering accommodation, including caravans, camper vans, motor homes, camper trailers and livestock or car transporters with accommodation included. (b) Vehicles such as food and drink vending vans and trailers, walk-through educational display caravans and trailers, mobile classrooms and television outside broadcast vans.(c) Transportable structures such as relocatable homes, transportable huts, tents for accommodation, and rigid and non-rigid annexes to vehicles referred to in (a) and (b).(d) Temporary site offices, cloakrooms, meeting offices, dormitories, canteens, toilets or other facilities provided on construction and demolition sites.NOTE: Specific construction or demolition activities are subject to the requirements of AS/NZS 3012.(e) Display units not intended for occupation, e.g. mobile electronic score boards and advertising signs, mobile traffic information signs.(f) In New Zealand, mobile medical connectable installations complying with the requirements of this Standard.NOTE: Further requirements for mobile medical connectable installations can be found in NZS 6115. This Standard does not apply to the following electrical installations:(i) Transportable structures with a permanently connected electricity supply and not intended to be relocated, e.g. tramcars, buses or caravans rendered immobile, and transportable sheds.These structures are subject to the requirements of AS/NZS 3000.(ii) Vehicles with fixed wiring that are amusement rides or concessions. These vehicles are subject to the requirements of AS 3533.(iii) Transportable structures without fixed wiring, for the provision of entertainment. e.g. circus and carnival tents, temporary vending stalls.These structures are subject to the requirements of AS/NZS 3002.(iv) Pleasure craft as defined in AS/NZS 3004.2.

Committee
EL-001
DevelopmentNote
Under Revision by DR AS/NZS 3001.1:2021 and DR AS/NZS 3001.2:2021.
DocumentType
Standard
ISBN
0 7337 8968 4
Pages
40
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
SupersededBy
Supersedes
UnderRevision

First published as AS 3001-1959.Second edition 1966.Third edition 1977.Fourth edition 1981.AS 3005 first published 1982.Fifth edition AS 3001-1985.Sixth edition 1990.AS 3001-1990 and AS 3005-1982 jointly revised, amalgamated and redesignated as AS/NZS 3001:2001.Eighth edition 2008. Originated as AS 3001-1959 and AS 3005-1982. Previous edition AS 3001-2001. Eighth edition 2008. Reissued incorporating Amendment No. 1 (June 2012).

AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3533.4.3-2007 Amusement rides and devices Specific requirements - Roller coasters
AS 3533.2 SUPP 1-1997 Amusement rides and devices Operation and maintenance - Logbook (Supplement to AS 3533.2-1997)
AS/NZS 3002:2008 Electrical installations - Shows and carnivals
AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
AS 3533.1 SUPP 1-2003 Amusement rides and devices Design and construction - Intrinsic safety (Supplement to AS 3533.1-1997)
AS 3533.2-1997 Amusement rides and devices - Operation and maintenance
AS 3533.4.1-2005 Amusement rides and devices Specific requirements - Land-borne inflatable devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 3105:2007 Approval and test specification - Electrical portable outlet devices
AS/NZS 3120:1999 Approval and test specification - Cord extension sockets
AS/NZS 3003:2003 Electrical installations - Patient treatment areas of hospitals and medical, dental practices and dialyzing locations
AS/NZS 60320.1:2004 Appliance couplers for household and similar general purposes General requirements (IEC 60320-1, Ed. 2.0 (2001) MOD)
AS/NZS 3010:2005 Electrical installations - Generating sets
AS/NZS 60598.2.8:1998 Luminaires Particular requirements - Handlamps
AS/NZS 3112:2004 Approval and test specification - Plugs and socket-outlets
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS 3533.3-2003 Amusement rides and devices In-service inspection (Reconfirmed 2013)
AS/NZS 61009.1:2004 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD)
AS/NZS 3199:2007 Approval and test specification - Cord extension sets
AS/NZS 3128:1998 Approval and test specification - Portable lamp standards and brackets
AS/NZS 60598.2.8:2002 Luminaires Particular requirements - Handlamps (IEC 60598-2-8:2001, MOD)
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS 5601-2004 Gas installations
AS/NZS 4763(INT):2006 Safety of Portable Inverters
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)
AS 3533.1-1997 Amusement rides and devices - Design and construction

AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 5761:2011 In-service safety inspection and testing - Second-hand equipment prior to sale
AS/NZS 3002:2008 Electrical installations - Shows and carnivals
AS/NZS 5762:2011 In-service safety inspection and testing - Repaired electrical equipment
AS/NZS 3190:2009 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3190:2011 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
AS/NZS 3760:2010 In-service safety inspection and testing of electrical equipment

View more information
$145.75
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more