00/560160 DC : DRAFT JAN 2000

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

BS ISO 15197 DETERMINATION OF PERFORMANCE CRITERIA FOR IN VITRO BLOOD GLUCOSE MONITORING SYSTEMS FOR MANAGEMENT OF HUMAN DIABETES MELLITUS
Superseded date

27-05-2003

Published date

23-11-2012

Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Design
   4.1 Ergonomic/human factor aspects
   4.2 Risk analysis
5 Labelling and documentation
   5.1 Blood glucose monitor labels
   5.2 User manual for the blood glucose monitoring
       system
   5.3 Reagent system and control material labels
   5.4 Reagents and control material inserts
6 Blood glucose monitor design and interference
   aspects
   6.1 Protection against electric shock and patient
       leakage current
   6.2 Protection against mechanical hazards
   6.3 Baseline performance test
   6.4 Mechanical resistance to shock, vibration,
       and impact
       6.4.1 Vibration test protocol
       6.4.2 Drop test protocol
   6.5 Equipment humidity exposure test protocol
       6.5.1 High temperature test protocol
       6.5.2 Low temperature test protocol
   6.6 Resistance to heat
   6.7 Resistance to moisture and liquids
   6.8 Protection against liberated gases, explosion,
       and implosion
   6.9 Components
       6.10 Equipment humidity exposure test protocol
7 Technical performance evaluation
   7.1 Imprecision testing
       7.1.1 General
       7.1.2 Within run imprecision test protocol
       7.1.3 Total imprecision (day-to-day) test
       7.1.4 Data presentation
   7.2 Accuracy testing
       7.2.1 General
       7.2.2 Materials/Methods
       7.2.3 Run format
       7.2.4 Data presentation
   7.3 Minimum acceptable performance
8 User performance evaluation
   8.1 Selection of user groups
   8.2 Selection of evaluation sites
   8.3 User instructions
   8.4 User techniques
Annex A (informative) Analytical Performance
        Requirements for Self-Monitoring of
        Blood Glucose for the Contro of Diabetes
        Mellitus
   A.1 Purpose
   A.2 Introduction
   A.3 Currently Accepted Performance Criteria
   A.4 Current state-of-the-art
   A.5 Clinical Studies
   A.6 Conclusions
Bibliography

Committee
CH/69
DocumentType
Draft
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

CSA Z316.4 : 0 PERFORMANCE SPECIFICATIONS FOR PORTABLE WHOLE BLOOD GLUCOSE MONITOR SYSTEMS FOR USE IN DIABETES MANAGEMENT
EN 592 : 2002 INSTRUCTIONS FOR USE FOR IN VITRO DIAGNOSTIC INSTRUMENTS FOR SELF-TESTING
EN 376 : 2002 INFORMATION SUPPLIED BY THE MANUFACTURER WITH IN VITRO DIAGNOSTIC REAGENTS FOR SELF-TESTING
ISO 17511:2003 In vitro diagnostic medical devices Measurement of quantities in biological samples Metrological traceability of values assigned to calibrators and control materials
ISO 14971-1:1998 Medical devices Risk management Part 1: Application of risk analysis
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more