Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

09/30193520 DC : 0

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

BS EN 60947-5-3 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDF)
Available format(s)

Hardcopy , PDF

Superseded date

31-12-2013

Language(s)

English

1 General
  1.1 Scope
  1.2 Normative references
2 Terms, definitions and abbreviations
  2.1 General
  2.2 Alphabetic index of terms
  2.3 Basic terms and definitions
  2.4 Terms and definitions concerning the integrity
  2.5 Terms and definitions concerning the architectural
       constraints
  2.6 Terms and definitions concerning the parts of a PDDB
  2.7 Terms and definitions concerning the operation of
       a PDDB
  2.8 Abbreviations
3 Classification
4 Characteristics
  4.5 Constructional characteristics
5 Product information
  5.1 Nature of information
  5.2 Identification
  5.3 Marking
  5.4 Instructions for installation, operation and
       maintenance
6 Normal service, mounting and transport conditions
  6.1 Normal service conditions
  6.2 Conditions during transport and storage
  6.3 Mounting
7 Constructional and performance requirements
  7.1 Constructional requirements
  7.2 Functional safety management requirements
  7.3 Information for use
  7.4 Validation and tests of the PDDB
8 Tests
  8.1 Kind of tests
  8.2 Compliance with constructional requirements
  8.3 Performances
  8.4 Verification of operating distances
  8.5 Verification of resistance to vibration and shock
  8.6 Verification of electromagnetic compatibility
9 Modification
  9.1 Objective
  9.2 Modification procedure
Annex A (informative) - Example of a simple control system
        in accordance with IEC 61511
  A.1 Description
  A.2 Safety requirements specification
  A.3 Realisation
  A.4 Collection of the data
  A.5 Results
Annex B (informative) - Example using IEC 62061
Annex C (informative) - Example using ISO 13849-1

BS EN 60947-5-3

Committee
PEL/17/2
DocumentType
Draft
Pages
47
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
ISO 14119:2013 Safety of machinery Interlocking devices associated with guards Principles for design and selection
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 61508-5:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508)
IEC 61165:2006 Application of Markov techniques
IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
IEC TR 62380:2004 Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 13849-2:2012 Safety of machinery — Safety-related parts of control systems — Part 2: Validation
IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
ISO 630:1995 Structural steels Plates, wide flats, bars, sections and profiles
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60947-5-2:2007+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches
IEC 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
ISO 13849-1:2015 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design
IEC 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508)
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$39.22
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more