BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS
Available format(s)

Hardcopy , PDF

Superseded date

30-09-2013

Language(s)

English

Section 1 - General
Section 2 - Surge arrester fundamentals and
            applications issues
Section 3 - Insulation Co-ordination and Surge
            Arrester Applications
Section 4 - Surge arresters for special applications
Section 5 - Asset management of surge arresters
Annex A (Informative) - Determination of temporary
        overvoltages due to earth faults
Annex B (Informative) - Current practice
Annex C (Informative) - Arrester modelling techniques
        for studies involving insulation
         co-ordination and energy requirements
Annex D (Informative) - Diagnostic indicators of
        metal-oxide surge arresters in service
Annex E (Informative) - Typical data needed from
        arrester manufacturers for proper
        selection of surge arresters
Annex F (Informative) - Glossery
Annex G (Informative) - Bibliography
Annex H (Informative) - End of life and replacement
        of old gapped SiC-arresters

BS EN 60099-5

Committee
PEL/37
DocumentType
Draft
Pages
131
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
IEC 60099-6:2002 Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems

View more information
$86.27
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more