16/30282633 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Hardcopy , PDF
31-10-2017
English
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
5 Electrical service conditions
6 Reliability, maintainability and expected useful life
7 Design
8 Non-railway designed electronic equipment
9 Components
10 Construction
11 Safety
12 Documentation
13 Testing
Annex A (informative) - List of default requirements of
the EN 50155 and related clauses
Annex B (informative) - Testing approach
Annex C (informative) - Severity of the service conditions
in different rolling stock locations
Annex D (informative) - Example of test report compliance
summary
Annex E (informative) - Life cycle model examples
Annex F (informative) - Design guidelines for electronic
hardware used on board of rolling stock
Annex G (informative) - Non-railway designed electronic
equipment
Bibliography
BS EN 50155.
Committee |
GEL/9/2
|
DocumentType |
Draft
|
Pages |
104
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 50155 : DRAFT 2016 | Identical |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
NASA HDBK 4008 : 2013 | PROGRAMMABLE LOGIC DEVICES (PLD) HANDBOOK |
IPC A 600 : H | ACCEPTABILITY OF PRINTED BOARDS |
DIN 5510-2:2009-05 | PREVENTIVE FIRE PROTECTION IN RAILWAY VEHICLES - PART 2: FIRE BEHAVIOUR AND FIRE SIDE EFFECTS OF MATERIALS AND PARTS - CLASSIFICATION, REQUIREMENTS AND TEST METHODS |
EN 60352-2:2006/A1:2013 | SOLDERLESS CONNECTIONS - PART 2: CRIMPED CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
ISO/IEC/IEEE 15288:2015 | Systems and software engineering — System life cycle processes |
IEC 61123:1991 | Reliability testing - Compliance test plans for success ratio |
EN 60297-3-100:2009 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets |
EN 123300 : 1992 AMD 1 1995 | SECTIONAL SPECIFICATION: MULTILAYER PRINTED BOARDS |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
EN 123200:1992/A1:1995 | SECTIONAL SPECIFICATION: SINGLE AND DOUBLE SIDED PRINTED BOARDS WITH PLATED-THROUGH HOLES |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60319:1999 | Presentation and specification of reliability data for electronic components |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 61014:2003 | Programmes for reliability growth |
IEC 61249-2-7:2002 | Materials for printed boards and other interconnecting structures - Part 2-7: Reinforced base materials clad and unclad - Epoxide woven E-glass laminated sheet of defined flammability (vertical burning test), copper-clad |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
IEC 61070:1991 | Compliance test procedures for steady-state availability |
EN 60249-2-15 : 1994 AMD 1 1994 | BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 15: FLEXIBLE COPPER-CLAD POLYIMIDE FILM, OF DEFINED FLAMMABILITY |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
EN 61249-2-10:2003/corrigendum:2005 | Materials for printed boards and other interconnecting structures - Part 2-10: Reinforced base materials, clad and unclad - Cyanate ester, brominated epoxide, modified or unmodified, woven E-glass reinforced laminated sheets of defined flammability (vertical burning test), copper-clad |
MIL-HDBK-781 Revision A:1996 | RELIABILITY TEST METHODS, PLANS, AND ENVIRONMENTS FOR ENGINEERING DEVELOPMENT, QUALIFICATION AND PRODUCTION |
EN 123000:1991/A2:1996 | GENERIC SPECIFICATION: PRINTED BOARDS |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
EN 61163-1 : 2006 | RELIABILITY STRESS SCREENING - PART 1: REPAIRABLE ASSEMBLIES MANUFACTURED IN LOTS |
IEC 61163-1:2006 | Reliability stress screening - Part 1: Repairable assemblies manufactured in lots |
EN 61249-2-7:2002/corrigendum:2005 | MATERIALS FOR PRINTED BOARDS AND OTHER INTERCONNECTING STRUCTURES - PART 2-7: REINFORCED BASE MATERIALS CLAD AND UNCLAD - EPOXIDE WOVEN E-GLASS LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST), COPPER-CLAD |
IEC TR 62380:2004 | Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment |
ISO/IEC/IEEE 15289:2017 | Systems and software engineering Content of life-cycle information items (documentation) |
IPC A 610 : F | ACCEPTABILITY OF ELECTRONIC ASSEMBLIES |
IPC 4101 : D | SPECIFICATION FOR BASE MATERIALS FOR RIGID AND MULTILAYER PRINTED BOARDS |
IEC 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50125-1:2014 | Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment |
IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 61124:2012 | Reliability testing - Compliance tests for constant failure rate and constant failure intensity |
IPC 2221B:2012 | GENERIC STANDARD ON PRINTED BOARD DESIGN |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO/IEC 12207:2008 | Systems and software engineering Software life cycle processes |
EN 50121-3-1:2017 | Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 123500:1992/A2:1995 | SECTIONAL SPECIFICATION: FLEXIBLE PRINTED BOARDS WITH THROUGH CONNECTIONS |
EN 45545-2:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
ISO 9001:2015 | Quality management systems — Requirements |
PREN 50657 : DRAFT 2016 | RAILWAY APPLICATIONS - ROLLING STOCK APPLICATIONS - SOFTWARE ON BOARD OF ROLLING STOCK, EXCLUDING RAILWAY CONTROL AND PROTECTION APPLICATIONS |
IEC 61249-2-10:2003 | Materials for printed boards and other interconnecting structures - Part 2-10: Reinforced base materials clad and unclad - Cyanate ester, brominated epoxide, modified or unmodified, woven E-glass reinforced laminated sheets of defined flammability (vertical burning test), copper-clad |
IPC 2222 : A | SECTIONAL DESIGN STANDARD FOR RIGID ORGANIC PRINTED BOARDS |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
EN 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 123400:1992/A2:1995 | HARMONIZED SYSTEM OF QUALITY ASSESSMENT FOR ELECTRONIC COMPONENTS - SECTIONAL SPECIFICATION - FLEXIBLE PRINTED BOARDS WITHOUT THROUGH CONNECTIONS |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO/IEC 90003:2014 | Software engineering Guidelines for the application of ISO 9001:2008 to computer software |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 61287-1:2014/AC:2014 | RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS (IEC 61287-1:2014) |
EN 61000-4-17:1999/A2:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST |
IPC 6013 : C | QUALIFICATION AND PERFORMANCE SPECIFICATION FOR FLEXIBLE/RIGID-FLEXIBLE PRINTED BOARDS |
IPC 2581 : B | GENERIC REQUIREMENTS FOR PRINTED BOARD ASSEMBLY PRODUCTS MANUFACTURING DESCRIPTION DATA AND TRANSFER METHODOLOGY |
IPC 2223 : C | SECTIONAL DESIGN STANDARD FOR FLEXIBLE/RIGID-FLEXIBLE PRINTED BOARDS |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.