92/39915 DC : DRAFT APRIL 1992
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
23-07-2013
23-11-2012
Foreword
1 Scope
2 Definitions
2.1 Heat detecting cable
2.2 Integrating heat detecting cable
2.3 Non-integrating heat detecting cable
2.4 Interfacing equipment
2.5 Alarm threshold equipment
2.6 Local protection application
2.7 Space protection equipment
3 Field of application
4 Marking and documentation
5 General requirements for testing
5.1 Atmospheric conditions for test
5.2 Simulation of fire alarm conditions
5.3 Sensing element test specimen lengths
6 Requirements for fault monitoring
6.1 Requirements for fault monitoring
6.2 Monitoring of wiring
6.3 Object
6.4 Test apparatus
6.5 Test procedure
6.6 Pass criteria
7 Time temperature response tests
7.1 General
7.2 Test requirements for integrating type sensing
elements
7.3 Test requirements for non integrating type sending
elements
8 Voltage test for sensing elements
8.1 Object
8.2 Test voltage
8.3 Test procedures
8.4 Test pass criteria
9 Cold bend testing of sensing elements
9.1 Introduction - flexibility categories
9.2 Object
10 Ageing test for sensing elements
10.1 Object
10.2 Test apparatus
10.3 Test procedure
10.4 Test pass criteria
11 Tensile testing of sensing elements
11.1 Object
11.2 Test apparatus
11.3 Test procedure
11.4 Test pass criteria
12 Snatch testing of sensing elements
12.1 Object
12.2 Test apparatus
12.3 Test procedure
12.4 Test pass criteria
13 Impact test on sensing elements
13.1 Object
13.2 Test apparatus
13.3 Test procedure
13.4 Test pass criteria
14 Environmental withstand tests for interfacing and alarm
threshold equipment
14.1 General
14.2 Climatic environmental withstand tests
14.3 Mechanical shock test
14.4 Vibration test
14.5 Electrostatic discharge (E.S.D.) test
14.6 Fast Voltage transient test
14.7 Voltage variation test
14.8 Radiated RF fields test
Figures
1 Requirements for fault monitoring
2 Ambient temperature withstand test (Integrating heat
detecting cables)
3 Slow rate of rise of temperature response and consistency
test
4 Response to a step input of temperature test (Integrating
heat detecting cables)
5 Respond before destruction test
6 Response to a step input of temperature test
(Non-integrating heat detecting cables)
7 Voltage test for sensing elements
8 Cold bend testing of sensing elements
9 Tensile testing of sensing elements
10 Snatch testing of sensing elements
11 Impact test on sensing elements
12 Climatic environmental withstand test configuration
Publications referred to