VENTRICULAR ASSIST AND HEART REPLACEMENT SYSTEMS
Available format(s)

Hardcopy , PDF

Superseded date

08-03-2010

Language(s)

English

Published date

01-01-2000

Committee representation
Foreword
Introduction
1 Scope
2 References
3 Definitions and abbreviations
4 Intended clinical use and indications
5 System description
   5.1 Principle of operation
   5.2 Design consideration
   5.3 System configuration
   5.4 System performance and operating limits
   5.5 Design analysis
   5.6 Risk analysis
   5.7 Human factors
        5.7.1 General
        5.7.2 Specific human factors considerations
6 In vitro design evaluation
   6.1 In vitro test setup
   6.2 "Worst-case" operating conditions
   6.3 Fluid dynamics
   6.4 Software verification and validation
   6.5 Electrical qualification
        6.5.1 Electromagnetic compatibility
        6.5.2 Electrical safety
   6.6 Power sources
        6.6.1 Transcutaneous energy transmission systems
        6.6.2 Batteries
   6.7 Mechanical qualification
        6.7.1 Connections and connectors
               6.7.1.1 Electrical
               6.7.1.2 Pneumatic/gas
               6.7.1.3 Blood/conduits
        6.7.2 Vascular grafts
        6.7.3 Valves
        6.7.4 Materials qualification
   6.8 Biocompatibility
   6.9 Environmental testing
7 In vivo design evaluation
   7.1 In vivo study plan
   7.2 In vivo protocol
   7.3 In vivo analysis plan
8 Reliability
9 Clinical trial considerations
10 Labeling
   10.1 General
   10.2 Instructions for use
        10.2.1 General
        10.2.2 Contra-indications and associated precautions
        10.2.3 Human factors considerations
Annexes
A - Rationale for the development and provisions of this
    technical information report
B - Example environmental testing matrix
C - Bibliography

Gives guidelines for gathering data and information to demonstrate the safety and effectiveness of ventricular assist and heart replacement systems for patients with heart dysfunction.

Committee
MC
DocumentType
Standard
Pages
27
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy

ISO 14708-5:2010 Implants for surgery Active implantable medical devices Part 5: Circulatory support devices

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
ASTM D 4169 : 2016 : REDLINE Standard Practice for Performance Testing of Shipping Containers and Systems
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
CFR 21(PTS800-1299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60801-1:1984 Electromagnetic compatibility for industrial-process measurement and control equipment. Part 1: General introduction
AAMI VP20 : 2ED 94 CARDIOVASCULAR IMPLANTS - VASCULAR GRAFT PROSTHESES
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
AAMI ISO 15223 : 2000 AMD 2 2004 MEDICAL DEVICES - SYMBOLS TO BE USED WITH MEDICAL DEVICE LABELS, LABELING, AND INFORMATION TO BE SUPPLIED
AAMI/ISO 13485:2016 MEDICAL DEVICES - QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS FOR REGULATORY PURPOSES

View more information
$134.22
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more