Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AHRI 1230 : 2010 ADD 2 2014

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

PERFORMANCE RATING OF VARIABLE REFRIGERANT FLOW (VRF) MULTI-SPLIT AIR-CONDITIONING AND HEAT PUMP EQUIPMENT
Superseded date

11-11-2021

Published date

12-01-2013

Section 1. Purpose
Section 2. Scope
Section 3. Definitions
Section 4. Classifications
Section 5. Test Requirements
Section 6. Rating Requirements
Section 7. Minimum Data Requirements for Published Ratings
Section 8. Operating Requirements
Section 9. Marking and Nameplate Data
Section 10. Conformance Conditions
APPENDICES
Appendix A - References - Normative
Appendix B - References - Informative
Appendix C - Uniform Test Method for Measuring the Energy
             Consumption of Central Air Conditioners and Heat
             Pumps - Normative
             Appendix M to Subpart B of Part 430 - Uniform Test
             Method for Measuring the Energy Consumption of Central
             Air Conditioners and Heat Pumps
Appendix D - Test Requirements - Normative
Appendix E - Heat Recovery Test Method - Normative
Appendix F - Individual Indoor Unit Capacity Tests - Normative
Appendix G - Prescriptive Methodology for the Cyclic Testing Of
             Ducted Systems - Normative
Appendix H - Integrated Part-Load Values (IPLV) - Normative

Describes matched variable refrigerant flow Multi-Split Air Conditioners and Multi-Split Heat Pumps using distributed refrigerant technology with cooling and heating capacities for outdoor units from 12,000 Btu/h [3508 W] to 300,000 Btu/h [90,000 W] and indoor units from 5,000 Btu/h [1,000W] to 60,000 Btu/h [20,000 W].

DocumentType
Standard
PublisherName
Air-Conditioning, Heating and Refrigeration Institute
Status
Superseded

ASHRAE 189.1 : 2014 DESIGN OF HIGH-PERFORMANCE GREEN BUILDINGS
AHRI 270 : 2008 SOUND PERFORMANCE RATING OF OUTDOOR UNITARY EQUIPMENT
AHRI 350 : 2000 SOUND PERFORMANCE RATING OF NON-DUCTED INDOOR AIR-CONDITIONING AND HEAT PUMP EQUIPMENT
AHRI 261 (SI) : 2017 SOUND RATING OF DUCTED AIR MOVING AND CONDITIONING EQUIPMENT
AHRI 1350 (I-P) : 2014 ADD 1 2015 MECHANICAL PERFORMANCE RATING OF CENTRAL STATION AIR-HANDLING UNIT CASINGS
AHRI 260 (I-P) : 2017 SOUND RATING OF DUCTED AIR MOVING AND CONDITIONING EQUIPMENT
AHRI 1351 (SI) : 2014 ADD 1 2015 MECHANICAL PERFORMANCE RATING OF CENTRAL STATION AIR-HANDLING UNIT CASINGS
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
ASHRAE 90.4 : 2016 ENERGY STANDARD FOR DATA CENTERS

IEC 60038:2009 IEC standard voltages
AHRI 340/360 : 2007 PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL UNITARY AIR-CONDITIONING AND HEAT PUMP EQUIPMENT
AHRI 110 : 2002 AIR-CONDITIONING, HEATING AND REFRIGERATING EQUIPMENT NAMEPLATE VOLTAGES
ASHRAE 37 : 2009 METHODS OF TESTING FOR RATING ELECTRICALLY DRIVEN UNITARY AIR-CONDITIONING AND HEAT PUMP EQUIPMENT
AHRI 365 (I-P) : 2009 PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL UNITARY AIR-CONDITIONING CONDENSING UNITS
ISO 5151:2017 Non-ducted air conditioners and heat pumps — Testing and rating for performance
AHRI 210/240 : 2006 PERFORMANCE RATING OF UNITARY AIR-CONDITIONING AND AIR-SOURCE HEAT PUMP EQUIPMENT
ISO 5167:1980 Measurement of fluid flow by means of orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full
CFR 10(PTS400-499) : JAN 96 ENERGY
ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct
ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more