SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS
Available format(s)

Hardcopy , PDF

Superseded date

29-01-2010

Language(s)

English

Published date

01-01-2009

1. Scope
2. Referenced standards
3. Distribution class open, enclosed and open-link
   fuses and cutouts and fuse disconnecting switches
4. Fuse links for distribution class open, enclosed,
   and open-link fuses and cutouts

Sets up specifications for high voltage (above 1000 volts) expulsion type distribution class fuses, cutouts, fuse disconnecting switches, fuse links and associated accessories. All of these devices are intended for use on alternating current distribution systems.

DevelopmentNote
Redesignated as IEEE C37.42. (03/2010)
DocumentType
Standard
Pages
42
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE DRAFT C37.48 : D5 NOV 96 GUIDE FOR APPLICATION, OPERATION AND MAINTENANCE OF HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE DRAFT C37.48.1 : D13 2000 DRAFT GUIDE FOR THE OPERATION, CLASSIFICATION, APPLICATION AND COORDINATION OF CURRENT-LIMITING FUSES WITH RATED VOLTAGES 1-38 KV
A-A-55498 Revision F:2017 FUSE LINK, ELECTRICAL, TYPE T (SLOW)
A-A-55497 Revision F:2017 FUSE LINK, ELECTRICAL, TYPE K (FAST)
IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE DRAFT C37.108 : D6 98 DRAFT GUIDE FOR THE PROTECTION OF NETWORK TRANSFORMERS
CSA C310 : 2009 : R2014 DISTRIBUTION CLASS POLYMERIC CUTOUTS
NEMA SG 2 : 1993 HIGH VOLTAGE FUSES
ANSI C37.44 : 1981 AMERICAN NATIONAL STANDARD SPECIFICATIONS FOR DISTRIBUTION OIL CUTOUTS AND FUSE LINKS
CSA C310 : 2009 DISTRIBUTION CLASS POLYMERIC CUTOUTS
CSA C310 : 2009 : INC : UPD 2 : 2012 DISTRIBUTION CLASS POLYMERIC CUTOUTS
CSA C233.1 : 1987 GAPLESS METAL OXIDE SURGE ARRESTERS FOR ALTERNATING CURRENT SYSTEMS
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
IEEE C37.43-2008 IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors
IEEE 551 : 2006 CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
ASME B18.2.2 : 2015 NUTS FOR GENERAL APPLICATIONS: MACHINE SCREW NUTS, HEX, SQUARE, HEX FLANGE, AND COUPLING NUTS (INCH SERIES)
IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more