Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1531-1991

Current
Current

The latest, up-to-date edition.

Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

10-06-1991

Preview

Sets out requirements and tests necessary for homogeneous bare electrical conductors for overhead power transmission and constructed of all aluminium and aluminium alloy wires. A range of wire sizes, 2.50mm to 4.75mm, and their properties are provided.

This Standard specifies requirements and tests for homogeneous bare electrical conductors for overhead power transmission, and constructed of all aluminium or all aluminium alloy wires.NOTES:1 Appendix A gives methods to calculate conductor properties.2 Appendix B gives the coefficient of linear expansion and the theoretical basis for the calculation of modulus of elasticity.3 Appendix C lists code names which may be used to refer to specific type and construction of conductor.4 Appendix D lists information which should be supplied with enquiries and orders for conductors.

Committee
EL/10
DocumentType
Standard
ISBN
0 7262 6881 X
Pages
12
ProductNote
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
PublisherName
Standards Australia
Status
Current
Supersedes

First published as part of AS C75-1936 (endorsement of BS 215-1934 without amendment) AS C75-1936 revised and redesignated in part as AS C75.2-1965.Revised and redesignated AS 1531.1-1974.AS C75.3 first published 1965.Revised and redesignated AS 1531.2-1974.AS 1531.3 first published 1984.AS 1531.1-1974, AS 1531.2-1974 and AS 1531.3-1984 revised, amalgamated and redesignated AS 1531-1991.Reconfirmed 2016. AS 1531 first published as part of AS C75-1936 (endorsement of BS 215-1932 without amendment). AS C75-1936 revised and redesignated in part as AS C75.2-1965. Revised and redesignated AS 1531.1-1974. AS C75.3 first published 1965. Revised and redesignated AS 1531.2-1974. AS 1531.3 first published 1984. AS 1531.1-1974, AS 1531.2-1974 and AS 1531.3-1984 revised, amalgamated and redesignated AS 1531-1991.

AS 1391-2007 Metallic materials - Tensile testing at ambient temperature
AS 2505.5-1982 Methods for bend and related testing of metals - Torsion and wrapping tests on wire
AS/NZS 2857:1996 Timber drums for insulated electric cables and bare conductors
AS 2857-1986 Timber drums for insulated electric cables and bare conductors
AS 2505.5-2002 Metallic materials Wire - Simple torsion test
AS 2848.1-1998 Aluminium and aluminium alloys - Compositions and designations Wrought products (Reconfirmed 2018)
AS 1391-1991 Methods for tensile testing of metals
AS C365.2-1970 Drums for bare stranded conductors - Metal drums

AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS 3822(INT)-1998 Test methods for bare overhead conductors
AS/NZS 1768:2007 Lightning protection
AS/NZS 7000:2016 Overhead line design
AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS 3822-2002 Test methods for bare overhead conductors
HB 331-2012 Overhead line design
AS/NZS 3008.1.2:2010 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
DR 00391 Conductors - Covered overhead - For working voltages 6.35/11(12)kV up to and including 19/33(36)kV
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS/NZS 3008.1.1:2009 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 3675:2002 Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017)
AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 3008.1.2:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
AS 3675-1993 Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV
AS/NZS 1768(INT):2003 Lightning protection

View more information
$79.54
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more