AS 1735.15-1990

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Lifts, escalators and moving walks Lifts for people with limited mobility - Restricted use - Non-automatically controlled
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Language(s)

English

Published date

01-01-1990

Preview

1 - AS 1735.15-1990 LIFTS, ESCALATORS, AND MOVING WALKS - LIFTS FOR PEOPLE WITH LIMITED MOBILITY - RESTRICTED USE - NON-AUTOMATIC
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE.
6 - 2 APPLICATION.
6 - 3 INNOVATION.
6 - 4 REFERENCED DOCUMENTS.
6 - 5 DEFINITIONS.
6 - 6 DESIGN LIMITATIONS.
6 - 6.1 Speed.
6 - 6.2 Travel.
6 - 6.3 Rated load.
7 - 6.4 Car size.
7 - 6.5 Factor of safety.
7 - 7 MATERIALS.
7 - 7.1 General.
7 - 7.2 Weather resistance.
7 - 8 DRIVING MACHINES.
7 - 8.1 General.
7 - 8.2 Shafts and attachments.
7 - 8.3 Drive direction.
7 - 8.4 Manual operation.
7 - 8.5 Location of equipment.
7 - 9 SUSPENSION SYSTEMS AND SUPPORTING SYSTEMS.
7 - 9.1 Means.
7 - 9.2 Rope.
8 - 9.3 Chain.
9 - 9.4 Rack and pinion.
9 - 9.5 Hydraulics.
9 - 10 LIFTWAYS.
9 - 10.1 Supporting structure.
10 - 10.2 Enclosure.
10 - 10.3 Surface of liftway.
11 - 10.4 Top overtravel of car.
11 - 10.5 Car clearances.
11 - 11 GUIDE RAILS.
11 - 11.1 Provision.
11 - 11.2 Length.
12 - 11.3 Guide rails and associated fixings.
12 - 11.4 Stresses in and deflections of guide rails.
12 - 12 GUIDE SHOES.
12 - 13 BUFFERS.
12 - 13.1 Bottom buffers.
13 - 13.2 Top buffers.
13 - 14 SAFETY GEAR.
13 - 14.1 Provision.
13 - 14.2 Material.
13 - 14.3 Construction.
13 - 14.4 Actuation.
13 - 14.5 Release.
13 - 14.6 Performance.
13 - 15 COUNTERWEIGHTS.
13 - 15.1 General.
13 - 15.2 Guarding.
13 - 16 CARS.
13 - 16.1 Frame.
14 - 16.2 Enclosure.
14 - 16.3 Number of entrances.
14 - 16.4 Safety protection of car entrance.
14 - 16.5 Sides.
14 - 16.6 Car roof.
14 - 16.7 Ventilation.
14 - 17 DOORS AND GATES.
14 - 17.1 Provision of landing doors or gates.
15 - 17.2 Types.
15 - 17.3 Width.
15 - 17.4 Height.
15 - 17.5 Construction.
15 - 17.6 Power operation.
15 - 17.7 Self-closing of doors and gates on landings.
15 - 17.8 Vision panels.
16 - 18 DOOR LOCKS AND DOOR CONTACTS.
16 - 18.1 Cars.
16 - 18.2 Landings.
16 - 19 CONTROL DEVICES.
16 - 19.1 Location.
17 - 19.2 Key-lockable controls.
17 - 19.3 Operating control devices.
17 - 19.4 Reversing contactors.
17 - 19.5 Operating circuit.
17 - 19.6 Anti-creep levelling device.
17 - 20 ELECTRICAL.
17 - 20.1 Power supply.
18 - 20.2 Wiring.
18 - 20.3 Circuit-breaker or switch.
18 - 20.4 Motor protection.
18 - 20.5 Car stop switch.
18 - 20.6 Limit switches.
19 - 20.7 Reverse phase relay.
19 - 20.8 Safety gear switch.
19 - 20.9 Slack rope or chain switch.
19 - 20.10 Liftway flap switch.
19 - 20.11 Door-lock valve test switch.
19 - 20.12 Edge bar switches.
19 - 20.13 Safety pan switches.
19 - 21 LIGHTING.
19 - 21.1 Normal lighting.
19 - 21.2 Emergency lighting.
19 - 22 COMMUNICATION.
19 - 22.1 Provision.
20 - 22.2 Accessibility.
20 - 22.3 Telephone alarm system.
20 - 22.4 Audible alarm.
20 - 23 NOTICES.
20 - 23.1 Load plate.
20 - 23.2 Nameplate.
20 - 23.3 Emergency instructions.
22 - APPENDIX A - PERIODIC INSPECTION AND TESTING
22 - APPENDIX B - GUIDE FOR SELECTION OF THE PREFERRED TYPE OF LIFT

Specifies requirements for low-speed passenger lifts controlled by a constant pressure device. The lifts are capable of being electrically isolated by a key-lockable control. It is intended that the Standard be applied only where the lift is used infrequently, primarily by persons with limited mobility. Guidance on periodic inspection and testing, and on selection of the preferred type of lift are given in appendices.

This Standard specifies requirements for lowspeed passenger lifts controlled by a constant pressure device. The lifts are capable of being electrically isolated by a keylockable control.This Standard is complementary to AS 1735.1, but the requirements of this Standard take precedence over corresponding requirements of that Standard.NOTE: Guidance on periodic inspection and testing and on selection of the preferred type of lift are given in Appendices A and B respectively.

Committee
ME-004
DocumentType
Standard
ISBN
0 7262 6275 7
Pages
17
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Under Revision see DR 02013 CP

AS 1735.14-1998 Lifts, escalators and moving walks Low-rise platforms for passengers
AS 1735.7-1998 Lifts, escalators and moving walks Stairway lifts
AS 1735.2-2001 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 1428.2-1992 Design for access and mobility Enhanced and additional requirements - Buildings and facilities (Reconfirmed 2015)

View more information
$99.73
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more