AS 3953-1996

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Loading guide for dry-type power transformers

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

14-04-2023

Language(s)

English

Published date

05-02-1996

Preview

1 - AS 3953- 1996
4 - PREFACE
5 - CONTENTS
7 - 1. Scope
7 - 2. Object
8 - 3. Symbols
9 - PART 1
9 - 4. Basis of guide
9 - 4.1 Introduction
10 - 4.2 Parameters used in the calculations
11 - 4.3 Formulae
13 - 4.4 Determination of the overload applicable to a transformer with a given load diagram, on the basis of normal life cons...
14 - 4.5 Determination of the overload (value or duration) applicable to a transformer with a simplified load diagram, on the ...
16 - 5. Algorithm for basic “use of life” calculations
18 - 6. Limitations
18 - PART 2
18 - 7. Basis of establishing load curves
18 - 7.1 Typical load diagram
18 - 7.2 Parameters of the load curves
18 - 8. Selection of appropriate load curve with examples
32 - APPENDIX ZZ - VARIATIONS FROM IEC 905 REQUIRED FOR AUSTRALIAN CONDITIONS
32 - ZZ1 SCOPE
32 - ZZ2 LIST

Provides guidance and loading recommendations to naturally cooled dry-type transformers complying with AS 2735, and gives the method of calculating loading conditions. It also describes how dry-type transformers can operate without exceeding the acceptable limit of deterioration of insulation through thermal effects. It is identical with and reproduced from IEC 905:1987 and its Corrigendum 1991.

This guide is applicable to naturally cooled dry-type power transformers complying with IEC Publication 726 and operated within the limitations referred to in Clause 6. Six different insulation systems are taken into account, identified by their system temperatures. Because there are numerous combinations of different insulation systems and constructions it is possible to make loading recommendations only of a general nature. For this reason the guide is in two parts:- the first part makes no loading recommendations, but gives the method of calculating loading conditions when the variable parameters are known as the result of prototype testing of a particular construction and/or insulation system. The calculations are given in the form of an algorithm from which computer programs can be written;- the second part assumes constant values for the variable parameters, with the exception of the insulation temperature limits (Table I) and the temperature of external cooling air, irrespective of insulation system or construction, thereby enabling load curves to be produced.The guide indicates how dry-type transformers may be operated without exceeding the acceptable limit of deterioration of insulation through thermal effects. The acceptable limit of deterioration of insulation is defined as that which occurs when the dry-type transformer is operating under rated conditions at the basic temperature of the external cooling air.

Committee
EL-008
DocumentType
Standard
ISBN
0 7337 0212 0
Pages
26
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Standards Relationship
IEC 60905:1987 Identical

First published as AS 3953-1991.Second edition 1996. First published as AS 3953-1991. Second edition 1996.

AS 2735-1984 Dry-type power transformers
AS 2374.1-1997 Power transformers General

AS 60076.1-2005 Power transformers General (IEC 60076-1, Ed. 2.1 (2000) MOD)
AS 2374.8-2000 Power transformers Application guide
AS 60076.11-2006 Power transformers Dry-type transformers
AS 2374.1-1997 Power transformers General
AS 62271.202-2008 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
AS 61330-2005 High-voltage/low-voltage prefabricated substations
AS 60974.1-2006 Arc welding equipment Welding power sources (IEC 60974-1:2000, MOD)
AS 2374.2-1997 Power transformers Temperature rise

View more information
$99.73
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more