Guide for the selection of insulators in respect of polluted conditions
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

27-11-2020

Language(s)

English

Published date

01-01-1996

Preview

Provides guidance on the selection of insulators for use in polluted conditions. It is identical with and has been reproduced from IEC 815:1986.

This guide is mainly applicable to three-phase systems up to 525 kV (phase-to-phase). For higher voltages the possible non-linear performance of insulators is still under study.This guide is applicable to outdoor ceramic and glass insulators, used in a.c. systems, of the following types:- long-rod and traction line insulator;- cap and pin insulator;- pedestal type post and rigid pin insulator;- substation and line post insulator;- hollow insulator;- bushing.This guide cannot directly be used for special types of insulators such as insulators with conductive glaze, or covered, during the manufacturing, with any insulating material, for surge arresters and also for longitudinal insulation for open circuit-breakers. This guide does not deal with radio interference voltage, television interference voltage and audible noise, the intensity of which may be increased on some polluted insulators.

Committee
EL-010
DocumentType
Standard
ISBN
0 7337 0808 0
Pages
19
ProductNote
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC TR 60815:1986 Identical

First published as AS 4436-1996.Reconfirmed 2016. First published as AS 4436-1996.

AS 2947.2-1989 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Characteristics
AS 1824.2-1985 Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide
AS 1137.3-1981 Insulators - Porcelain and glass indoor and outdoor station post insulators (for voltages greater than 1000 V a.c.)
AS/NZS 2947.2:2002 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c.

AS 60076.1-2005 Power transformers General (IEC 60076-1, Ed. 2.1 (2000) MOD)
AS 60044.2-2007 Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD)
AS 3007.2-2004 Electrical installations - Surface mines and associated processing plant - General protection requirements
AS/NZS 7000:2016 Overhead line design
AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)
AS 62217-2007 Polymeric insulators for indoor and outdoor use with a nominal voltage > 1000 V - General definitions, test methods and acceptance criteria
AS 60044.1-2007 Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD)
AS/NZS 2947.2:2002 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c.
AS 4899-2007 Pin insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. (Reconfirmed 2018)
HB 331-2012 Overhead line design
AS/NZS 2947.1:1999 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator units
AS/NZS 2650:2000 Common specifications for high-voltage switchgear and controlgear standards
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 60305-2007 Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type
AS 60044.5-2004 Instrument transformers Capacitor voltage transformers
AS 62271.202-2008 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS IEC 60433-2007 Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type
AS 4398.2-2005 Insulators - Ceramic or glass - Station post for indoor or outdoor use - Voltages greater than 1000 V a.c. Tests (IEC 60168, Ed. 4.2 (2001) MOD)
AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)
AS 4435.4-1997 Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods and acceptance criteria for post insulator units
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant

View more information
$63.81
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more