Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 4747.6-2013

Current

Current

The latest, up-to-date edition.

Meters for non-urban water supply Installation and commissioning of open channel meters

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-02-2013

Preview

Sets out requirements for water meters for use in non-urban applications in open channel and part-filled applications. It primarily applies to metering for irrigation water.

This Standard sets out requirements for the installation and commissioning of meters complying with NMI M11-1 and AS 4747.3, for use in non-urban applications in open channel and part-filled pipe applications. The Standard principally covers metering for irrigation water.Two types of meter installations are covered in this Standard, as follows: (a)A ‘self-contained unit’—a meter that defines its own geometry, is able to be pattern-approved as a complete water meter, calibrated upon assembly and supplied by a single supplier.(b)A ‘modular metering system’—a device or group of instruments (which may be supplied as a pattern-approved metering system) that does not define the installation geometry and requires configuration after installation.NOTES: 1The requirements for these types of meters to demonstrate compliance with this Standard, and hence with the National Framework are set out and illustrated in Section 7 of AS 4747.3.2Meters with undefined or variable channel are not covered by this Standard. In this Standard, a meter installation is considered to include—(i)the meter, its indicating device and all ancillary equipment; and(ii)the upstream and downstream pipe or emplacement that may have a material effect on the meter unit. The Standard covers meters that operate under the following conditions:(A)Open channels.(B)Working water temperature range of 0.1°C to 30°C. The maximum admissible temperature is 50°C, which is the limiting condition for the meter.(C)Ambient temperature range of ?5°C to 55°C.(D)Ambient humidity range of 0% to 100% except for remote indicating devices where the range is 0% to 93%.

Committee
CE-024
DocumentType
Standard
ISBN
978 1 74342 356 1
Pages
11
PublisherName
Standards Australia
Status
Current
Supersedes

First published as ATS 4747.6—2008.Revised and redesignated AS 4747.6—2013. First published as ATS 4747.6-2008. Revised and redesignated AS 4747.6-2013.

AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged
AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
AS 4747.2-2013 Meters for non-urban water supply Technical requirements for closed conduit meters fully charged
AS 3778.1-2009 Measurement of water flow in open channels Hydrometric determinations - Vocabulary and symbols
AS 4747.1-2013 Meters for non-urban water supply Glossary of terms

AS 4747.1-2013 Meters for non-urban water supply Glossary of terms
AS 4747.2-2013 Meters for non-urban water supply Technical requirements for closed conduit meters fully charged
AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged

View more information
$79.54
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more