    Grid connection of energy systems via inverters - Inverter requirements

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  29-06-2017

    Language(s):  English

    Published date:  31-12-2001

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 4777.2-2002 GRID CONNECTION OF ENERGY SYSTEMS VIA INVERTERS - INVERTER REQUIREMENTS
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 NORMATIVE REFERENCES
    6 - 3 DEFINITIONS
    6 - 3.1 Electricity distribution network
    6 - 3.2 Grid
    7 - 3.3 Grid protection device
    7 - 3.4 Inverter
    7 - 3.5 Inverter energy system
    7 - 3.6 Islanding
    7 - 3.7 Nominal grid voltage
    7 - 3.8 Ripple control
    7 - 3.9 Uninterruptible power supply (UPS) system
    7 - 4 INVERTER REQUIREMENTS
    7 - 4.1 General
    7 - 4.2 Compatibility with electrical installation
    7 - 4.3 Power flow direction
    7 - 4.4 Power factor
    8 - 4.5 Harmonic currents
    8 - 4.6 EMC
    8 - 4.7 Voltage fluctuations and flicker
    8 - 4.8 Impulse protection
    8 - 4.9 Transient voltage limits
    9 - 4.10 Direct current injection
    10 - 4.11 Data logging and communications devices
    11 - APPENDIX A - POWER FACTOR TEST
    11 - A1 TEST SPECIFICATIONS
    12 - APPENDIX B - HARMONIC CURRENT LIMIT TEST
    12 - B1 TEST SPECIFICATIONS
    12 - B2 HARMONIC CURRENT LIMITS
    12 - B3 SUPPLY SOURCE DURING HARMONIC TESTS
    14 - APPENDIX C - TRANSIENT VOLTAGE LIMIT TEST
    14 - C1 GENERAL
    14 - C2 TEST SPECIFICATIONS
    14 - C3 TRANSIENT VOLTAGE LIMITS

    Abstract - (Show below) - (Hide below)

    Specifies requirements for inverters with ratings of up to 10 kVA for single-phase units, or 30 kVA for three-phase units, and intended for connection to the low-voltage electricity distribution network (grid).

    Scope - (Show below) - (Hide below)

    This Standard specifies the requirements for inverters, with ratings up to 10 kVA for single-phase units or up to 30 kVA for three-phase units, for the injection of electric power through an electrical installation to the electricity distribution network.NOTE: Although this Standard does not apply to larger systems, similar principles can be used for the design of such systems.

    General Product Information - (Show below) - (Hide below)

    Committee EL-042
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS 4777.2-2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 60038-2000 Standard voltages
    AS/NZS 61000.3.3:1998 Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A
    AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
    AS/NZS 60950:2000 Safety of information technology equipment (IEC 60950:1999, MOD)
    AS/NZS 61000.3.5:1998 Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 16 A
    AS 4777.3-2002 Grid connection of energy systems via inverters - Grid protection requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 4777.1-2002 Grid connection of energy systems via inverters - Installation requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective
Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more