AS/NZS 1660.5.5:2005

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Test methods for electric cables, cords and conductors Fire tests - Circuit integrity
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

23-02-2023

Language(s)

English

Published date

01-01-2005

Preview

1 - AS/NZS 1660.5.5:2005 TEST METHODS FOR ELECTRIC CABLES, CORDS AND CONDUCTORS - FIRE TESTS-CIRCUIT INTEGRITY
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.3.1 Circuit integrity
8 - SECTION 2 APPARATUS-FIRE ALONE AT A FLAME TEMPERATURE OF AT LEAST 750°C
8 - 2.1 GENERAL
8 - 2.2 TEST CONDITIONS
8 - 2.2.1 Test environment
8 - 2.3 TEST APPARATUS
8 - 2.3.1 Sample supporting system
9 - 2.3.2 Source of heat
9 - 2.3.3 Positioning of source of heat
10 - SECTION 3 APPARATUS-FIRE WITH SHOCK AT A TEMPERATURE OF AT LEAST 830°C
10 - 3.1 GENERAL
10 - 3.2 TEST CONDITIONS
10 - 3.2.1 Test environment
10 - 3.3 TEST APPARATUS
10 - 3.3.1 Test equipment
11 - 3.3.2 Test ladder and mounting
11 - 3.3.3 Source of heat
11 - 3.3.4 Shock producing device
12 - 3.3.5 Positioning of source of heat
13 - SECTION 4 PROCEDURES AND REQUIREMENTS-CABLES OF RATED VOLTAGE UP TO AND INCLUDING 0.6/1.0 kV
13 - 4.1 GENERAL
13 - 4.2 SAMPLE PREPARATION
13 - 4.3 CONTINUITY CHECKING ARRANGEMENTS
13 - 4.4 TEST PROCEDURE
13 - 4.4.1 Apparatus
13 - 4.4.2 Fuses
13 - 4.4.3 Sample and burner positioning
14 - 4.4.4 Electrical connections
14 - 4.4.5 Commencement of test
14 - 4.4.6 Test duration
15 - 4.5 PERFORMANCE REQUIREMENT
15 - 4.5.1 Flame application time
15 - 4.6 ACCEPTANCE CRITERIA
15 - 4.7 RETEST PROCEDURE
15 - 4.8 TEST REPORT
16 - SECTION 5 PROCEDURES AND REQUIREMENTS-ELECTRIC DATA CABLES
16 - 5.1 GENERAL
16 - 5.2 SAMPLE PREPARATION
16 - 5.3 CONTINUITY CHECKING ARRANGEMENT
16 - 5.4 TEST PROCEDURE
16 - 5.4.1 Apparatus
16 - 5.4.2 Fuses
16 - 5.4.3 Sample and burner positioning
17 - 5.4.4 Electrical connections
17 - 5.4.5 Commencement of test
17 - 5.4.6 Test duration
17 - 5.5 PERFORMANCE REQUIREMENT
17 - 5.5.1 Flame application time
18 - 5.5.2 Acceptance criteria
18 - 5.6 RETEST PROCEDURE
18 - 5.7 TEST REPORT
19 - SECTION 6 PROCEDURES AND REQUIREMENTS-OPTICAL FIBRE CABLES
19 - 6.1 GENERAL
19 - 6.2 SAMPLE PREPARATION
19 - 6.3 CONTINUITY CHECKING ARRANGEMENT
19 - 6.4 TEST PROCEDURE
19 - 6.4.1 Apparatus
19 - 6.4.2 Sample and burning positioning
19 - 6.4.3 Optical fibre connections
19 - 6.4.4 Commencement of test
19 - 6.4.5 Test duration
20 - 6.5 PERFORMANCE REQUIREMENT
20 - 6.5.1 Flame application time
20 - 6.5.2 Acceptance criteria
20 - 6.6 RETEST PROCEDURE
20 - 6.7 TEST REPORT
21 - SECTION 7 PROCEDURES AND REQUIREMENTS FOR FIRE WITH SHOCK-CABLES OF RATED VOLTAGE UP TO AND INCLUDING 0.6/1.0kV
21 - 7.1 GENERAL
21 - 7.2 TEST SAMPLE
21 - 7.2.1 Sample preparation
21 - 7.2.2 Sample mounting
21 - 7.3 CONTINUITY CHECKING ARRANGEMENTS
22 - 7.4 TEST PROCEDURE
22 - 7.4.1 Apparatus
22 - 7.4.2 Fuses
22 - 7.4.3 Sample and burning positioning
22 - 7.4.4 Electrical connections
23 - 7.4.5 Commencement of test
23 - 7.4.6 Test duration
23 - 7.5 PERFORMANCE REQUIREMENT
23 - 7.5.1 Flame application time
23 - 7.5.2 Acceptance criteria
24 - 7.6 RETEST PROCEDURE
24 - 7.7 TEST REPORT
37 - APPENDIX A - VERIFICATION PROCEDURE FOR BURNER SYSTEM
37 - A1 TEMPERATURE MEASURING ARRANGEMENT
37 - A2 VERIFICATION PROCEDURE
37 - A2.1 Positing the burner
37 - A2.2 Igniting the burner
37 - A2.3 Adjusting the burner
37 - A2.4 Temperature monitoring
37 - A2.5 Verification
37 - A2.6 Unsuccessful verification
37 - A2.7 Readjustment of distances
37 - A2.8 Recording positions
37 - A2.9 Unsuitable burner system
39 - APPENDIX B - GUIDANCE ON THE CHOICE OF RECOMMENDED BURNER SYSTEMS
39 - B1 BURNER AND VENTURI
39 - B2 MASS FLOWMETERS
39 - B3 INFLUENCE OF TEST CHAMBER VOLUME
39 - B4 INFLUENCE OF DRAUGHTS IN THE TEST CHAMBER
39 - APPENDIX C - FLOWMETER CALIBRATION CORRECTION FACTORS
40 - C1 GENERAL
40 - C2 EXAMPLE
40 - C2.1 General
41 - C2.2 Air supplied at 1 bar
41 - C2.3 Air supplied at 2.4 bar
42 - APPENDIX D - VERIFICATION PROCEDURE FOR THE SOURCE OF HEAT
42 - D1 Flame temperature
42 - D2 Temperature monitoring
42 - D3 Verification
42 - D4 Unsuccessful verification
42 - D5 Readjustment of distance
42 - D6 Recording positions
42 - D7 Unsuitable burner system
44 - APPENDIX E - FUSE CHARACTERISTIC CURVE

Specifies the apparatus, procedures and performance requirements to be used for testing cables required to maintain circuit integrity when subjected to fire under specified conditions.

This Standard specifies the test apparatus, the test procedure and the performance requirements to be used for testing cables of rated voltages up to 0.6/1.0kV, data cables and optical cables which are required to maintain circuit integrity when subject to fire alone. The test condition is based upon a flame with a controlled heat output corresponding to a temperature of a least 750°C.It also covers testing of cables of rated voltages up to 0.6/1.0kV when subject to fire and mechanical shock where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of a nominal 850°C. This method is intended for use when testing cables of greater than 20mm overall diameter.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 6669 2
Pages
38
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS/NZS 1660.5.5:1998.Second edition 2005. First published as AS/NZS 1660.5.5:1998. Second edition 2005.

AS 60269.3.1-2005 Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses

AS/NZS 4507:2006 Cables - Classification of characteristics when exposed to fire
AS/NZS 60702.1:2005 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables
AS/NZS 3155:1995 Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV
AS 60092.376-2005 Electrical installations in ships - Cables for control and instrumentation circuits 150/250 V (300 V)
AS 60092.350-2005 Electrical installations in ships Shipboard power cables - General construction and test requirements
AS 60092.353-2005 Electrical installations in ships Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and 3 kV

View more information
$135.16
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more