Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 2430.3.6:2004

AvailableSuperseded
AvailableSuperseded

An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Classification of hazardous areas Examples of area classification - Laboratories, including fume cupboards and flammable medical agents
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

20-05-2004

Preview

Specifies guidance on the classification of areas associated with laboratories, fume cupboards and the use of flammable medical agents. It includes specified examples of classification for such areas. To be read in conjunction with AS/NZS2430.3.1.

This Standard provides examples of area classification for areas associated with laboratories and fume cupboards and the use of flammable medical agents. It is part of the AS/NZS 2430.3 series, which recommends the classification of several commonly occurring situations and should be read in conjunction with AS/NZS 2430.3.1.

Committee
MS-011
DocumentType
Standard
ISBN
0 7337 5973 4
Pages
6
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes

First published in Australia as part of AS 1076.2-1977.AS 2430.1 first published 1981.AS 1076.2-1977 and AS 2430.1-1981 revised, amalgamated and designated AS 2430.1-1982.AS 2430.1-1982 revised and redesignated in part as AS 2430.3-1987.Second edition 1991.First published in New Zealand as part of NZS 6101P:1972.Revised and redesignated in part as NZS 6101.3:1991.AS 2430.3-1991 and NZS 6101.3:1991 revised, amalgamated and redesignated in part as AS/NZS 2430.3.6:1997.Second edition 2004. Originated in Australia as part of AS 1076.2-1977. Originated in New Zealand as part of NZS 6101P:1972. Previous edition AS/NZS 2430.3.6:1997. Second edition 2004. Reissued incorporating Amendment No. 1 (March 2007).

AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS/NZS 2430.3.1:2004 Classification of hazardous areas Examples of area classification - General
AS/NZS 2381.1:1999 Electrical equipment for explosive atmospheres - Selection, installation and maintenance General requirements
AS/NZS 2243.8:2001 Safety in laboratories - Fume cupboards

AS 4976-2008 The removal and disposal of underground petroleum storage tanks
AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS/NZS 1596:2002 The storage and handling of LP Gas
AS/NZS 2311:2009 Guide to the painting of buildings
AS/NZS 2982:2010 Laboratory design and construction
HB 29-2007 Communications cabling manual - Module 2: Communications cabling handbook
AS 4326-2008 The storage and handling of oxidizing agents
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS/NZS 1768:2007 Lightning protection
AS/NZS 2243.8:2014 Safety in laboratories Fume cupboards
AS/NZS 2243.8:2006 Safety in laboratories - Fume cupboards
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS 2714-2008 The storage and handling of organic peroxides (Reconfirmed 2021)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3780-2008 The storage and handling of corrosive substances
AS/NZS 60079.30.2:2007 Explosive atmospheres Electrical resistance trace heating - Application guide for design, installation and maintenance (IEC 60079-30-2, Ed. 1.0 (2007) MOD)
AS/NZS 2243.1:2005 Safety in laboratories Planning and operational aspects
AS/NZS 4240.1:2009 Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021)
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
AS/NZS 2430.3.8:2004 Classification of hazardous areas Examples of area classification - Surface coatings and adhesives
AS/NZS 3788:2006 Pressure equipment - In-service inspection (Reconfirmed 2017)
AS 5034-2005 Installation and use of inert gases for beverage dispensing
HB 13-2007 Electrical equipment for hazardous areas
AS/NZS 2381.2:2006 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d
AS/NZS 2243.2:2006 Safety in laboratories Chemical aspects

View more information
$57.13
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more