1 - AS/NZS 2803.1:1994 DOORS - SECURITY SCREEN - HINGED
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SCOPE AND GENERAL
7 - 1 SCOPE
7 - 2 APPLICATION
7 - 3 REFERENCED DOCUMENTS
7 - 4 DEFINITIONS
7 - 4.1 Deadlocking bolt
7 - 4.2 Door frame
8 - 4.3 Door framing
8 - 4.4 Grille
8 - 4.5 Security screen door
8 - 4.5.1 Type I
8 - 4.5.2 Type II
8 - 4.5.3 Type III
8 - 5 DESIGN AND CONSTRUCTION
8 - 5.1 Galvanic compatibility
8 - 5.2 Corrosion protection
8 - 5.2.1 Steel
8 - 5.2.2 Aluminium
8 - 5.3 Door framing
8 - 5.4 Corner joints
8 - 5.5 Grille
8 - 5.5.1 Type I infill materials
9 - 5.5.2 Type II infill materials
10 - 5.5.3 Type III infill materials
12 - 5.6 Hinges
12 - 5.7 Rivets
12 - 5.8 Screws
12 - 5.9 Locks
12 - 5.10 Lock fitting
12 - 5.11 Dimensions
13 - 6 PERFORMANCE
13 - 7 MARKING
13 - 7.1 General
13 - 7.2 Installation instructions
14 - APPENDIX A - METHOD OF TEST TO MEET THE PERFORMANCE REQUIREMENTS OF THIS STANDARD
14 - A1 SCOPE
14 - A2 PRINCIPLE
14 - A3 TEST SAMPLE
14 - A3.1 General
14 - A3.2 Hinges
14 - A3.3 Lock fittings
15 - A4 PREPARATION FOR TESTING
15 - A5 APPARATUS
20 - A6 TEST PROCEDURE
20 - A6.1 General
20 - A6.2 Method of application of forces to the infill material
20 - A6.3 Attack upon locks
21 - A6.4 Hinge attack
21 - A6.5 Centre pull
21 - A6.6 Bottom pull
21 - A6.7 Top pull
22 - A6.8 Shear test on infill material (only applicable to Type I and Type II infill materials)
22 - A6.9 Type II infill material force probe test
22 - A7 REPORT
22 - A7.1 Supplementary information
28 - APPENDIX B - IDENTIFICATION DETAILS FOR DOORS SUBMITTED FOR TYPE TESTING IN ACCORDANCE WITH AS/NZS 2803.1 APPENDIX A
36 - APPENDIX C - TEST SEQUENCE FLOW CHART
37 - APPENDIX D - MARKING

Specifies requirements for the design, construction and performance of single leaf hinged security screen doors. It does not apply to double leaf doors nor does it deal with the installation of security screen doors. It includes an appendix for the method of test for resistance to forced entry. It is intended for use by regulatory authorities and all persons concerned with the manufacture, installation and general requirements of hinged security screen doors.

This Standard specifies requirements for the design, construction and performance of hinged security screen doors (single leaf only), primarily used in residential situations.NOTES1 Double leaf doors can be constructed and tested in accordance with Appendix A and reported accordingly, in consultation with the testing authority.2 The parts of a door shall not be referred to in isolation as being the complete door, for example, the grille.3 Requirements for the installation of hinged security screen doors are set out in AS 2804, Installation of hinged security screen doors, which is currently under revision and expected to be available in parts -hinged and sliding, as joint Australian/New Zealand Standards. The effectiveness of security screen doors is dependent on the strength of the door, the adequacy of its installation in the door frame, and surrounds.

Committee
CS-023
DocumentType
Standard
ISBN
0 7262 8947 7
Pages
31
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Amendment 2 to AS/NZS 2803.1:1994 see DR 98558 CP. Draft Amendment 3 see DR 00384 CP. Under Revision see DR 02283 CP. Under Revision see DR 02285 CP First published as AS 2803-1985.Second edition 1987.Jointly revised and redesignated as Joint Standard AS/NZS 2803.1:1994. First published as AS 2803-1985. Second edition 1987. Jointly revised and redesignated as Joint Standard AS/NZS 2803.1:1994.

AS 1397-1993 Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated
AS 2105-1992 Inorganic zinc silicate paint
AS 4145.2-1993 Locksets - Mechanical locksets for doors in buildings
AS 2204-1978 Zinc-rich organic priming paint
AS 3715-1989 Metal finishing - Thermoset powder coatings for architectural applications
AS 1650-1989 Hot-dipped galvanized coatings on ferrous articles
AS 1231-1985 Aluminium and aluminium alloys - Anodized coatings for architectural applications

AS/NZS 4483.2:1999 Security screen doors and security window grilles - Methods of test Knife shear test
AS/NZS 2804.1:1995 Installation of security screen doors - Hinged
AS 4485.2-1997 Security for health care facilities - Procedures guide

View more information
$113.50
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more