Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 3013:1995

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electrical installations - Classification of the fire and mechanical performance of wiring systems
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

25-06-2021

Language(s)

English

Published date

05-03-1995

Preview

1 - AS/NZS 3013:1995 ELECTRICAL INSTALLATIONS - CLASSIFICATION OF THE FIRE AND MECHANICAL PERFORMANCE OF WIRING SYSTEMS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND APPLICATION
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED AND RELATED DOCUMENTS
6 - 1.3.1 Referenced documents
7 - 1.3.2 Related documents
7 - 1.4 DEFINITIONS
7 - 1.4.1 Busway
7 - 1.4.2 Circuit integrity
7 - 1.4.3 Enclosed wiring system
7 - 1.4.4 Fixings
7 - 1.4.5 May
7 - 1.4.6 Saddles
7 - 1.4.7 Shall
7 - 1.4.8 Should
7 - 1.4.9 Supports
7 - 1.4.10 Unenclosed wiring system
7 - 1.4.11 Wiring system
8 - SECTION 2 CLASSIFICATION SYSTEM
8 - 2.1 DESIGNATION
8 - 2.1.1 General
8 - 2.1.2 Basic designation
8 - 2.1.3 Single characteristic numeral designation
8 - 2.2 FIRST CHARACTERISTIC NUMERAL
8 - 2.2.1 Purpose
8 - 2.2.2 Ability to maintain circuit integrity
8 - 2.2.3 Compliance
9 - 2.3 SECOND CHARACTERISTIC NUMERAL
9 - 2.3.1 Purpose
9 - 2.3.2 Ability to maintain circuit integrity
9 - 2.3.3 Compliance
9 - 2.4 SUPPLEMENTARY LETTER W
9 - 2.4.1 Purpose
9 - 2.4.2 Ability to maintain circuit integrity
9 - 2.4.3 Compliance
10 - 2.5 EXAMPLES OF CLASSIFICATIONS
11 - SECTION 3 CLASSIFICATION OF FIRE-TESTED WIRING SYSTEMS
11 - 3.1 GENERAL
11 - 3.1.1 Wiring systems
11 - 3.1.2 Alternative testing for supports and fixings
11 - 3.2 ASSIGNMENT OF CLASSIFICATION
11 - 3.2.1 Of a wiring system
11 - 3.2.2 Of a specimen
11 - SECTION 4 CLASSIFICATION OF MECHANICALLY-TESTED WIRING SYSTEMS
11 - 4.1 GENERAL
11 - 4.2 ASSIGNMENT OF CLASSIFICATION
11 - 4.2.1 Of a wiring system
11 - 4.2.2 Of a specimen
12 - APPENDIX A - FIRE TEST METHOD - WIRING SYSTEMS
12 - A1 SCOPE
12 - A2 APPLICATION
12 - A3 PRINCIPLE
12 - A4 TEST SPECIMENS
13 - A5 APPARATUS
14 - A6 PROCEDURE
16 - A7 CRITERIA OF FAILURE
16 - A8 REPORTING OF RESULTS
17 - APPENDIX B- FIRE TEST METHOD - SUPPORTS AND FIXINGS
17 - B1 SCOPE
17 - B2 APPLICATION
17 - B3 PRINCIPLE
17 - B4 TEST SPECIMENS
17 - B5 APPARATUS
17 - B6 PROCEDURE
18 - B7 CRITERIA OF FAILURE
18 - B8 REPORTING OF RESULTS
19 - APPENDIX C - MECHANICAL TEST METHOD IMPACT TEST
19 - C1 SCOPE
19 - C2 APPLICATION
19 - C3 PRINCIPLE
19 - C4 TEST SPECIMENS
19 - C5 APPARATUS
20 - C6 PROCEDURE - CABLES AND BUSWAYS
21 - C7 PROCEDURE - CIRCULAR ENCLOSURES
21 - C8 PROCEDURE - NON-CIRCULAR ENCLOSURES
22 - C9 CRITERIA OF FAILURE
22 - C9.1 Cables and busways
22 - C9.2 Circular enclosures
22 - C9.3 Non-circular enclosures
22 - C10 REPORTING OF RESULTS
23 - APPENDIX D - MECHANICAL TEST METHOD - CUTTING TEST
23 - D1 SCOPE
23 - D2 APPLICATION
23 - D3 PRINCIPLE
23 - D4 TEST SPECIMENS
23 - D5 APPARATUS
24 - D6 PROCEDURE
25 - D7 CRITERIA OF FAILURE
25 - D8 REPORTING OF RESULTS
26 - APPENDIX E - MECHANICAL TEST METHOD SADDLES
26 - E1 SCOPE
26 - E2 PRINCIPLE
26 - E3 TEST SPECIMENS
26 - E4 APPARATUS
26 - E5 PROCEDURE
27 - E6 CRITERIA OF FAILURE
27 - E7 REPORTING OF RESULTS
29 - APPENDIX F - FIRE AND WATER TEST METHOD
29 - F1 SCOPE
29 - F2 APPLICATION
29 - F3 PRINCIPLE
29 - F4 TEST SAMPLES
29 - F5 APPARATUS
29 - F6 PROCEDURE
30 - F7 CRITERIA OF FAILURE
30 - F8 REPORTING OF RESULTS
31 - APPENDIX G - APPLICATIONS GUIDE
31 - G1 SUPPLY AND INSTALLATION
31 - G1.1 Test of all components
31 - G1.2 Instructions
31 - G2 PARTICULAR WIRING SYSTEM APPLICATIONS
31 - G3 FIRE PROTECTED WIRING SYSTEMS
32 - G4 MECHANICALLY PROTECTED WIRING SYSTEMS
32 - G4.1 General
32 - G4.2 Application of wiring systems
32 - G4.3 Unenclosed wiring systems
33 - G4.4 Enclosed wiring systems
33 - G5 GUIDE TO MECHANICAL PROTECTION CLASSIFICATION

Sets out a classification scheme for wiring systems according to their resistance to the hazards of fire and mechanical damage. Type tests to verify the level of protection provided by a wiring system are given. Intended for reference in other Standards which specify wiring systems with a degree of resistance to damage from fire or mechanical impact.

This Standard sets out a classification system for wiring systems according to their ability to -(a) maintain circuit integrity under fire conditions for a specified period; and(b) maintain circuit integrity against mechanical damage of specified severity.It specifies type tests to determine the performance of the various types of wiring system.NOTE: Elements of a wiring system may need replacement after exposure to a hazard.

Committee
EL-037
DocumentType
Standard
ISBN
0 7262 9590 6
Pages
29
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Under Revision see DR 02517 First published in Australia as AS 3013-1990.Jointly revised and designated as Joint Standard AS/NZS 3013:1995. First published in Australia as AS 3013-1990. Jointly revised and designated as Joint Standard AS/NZS 3013:1995.

AS 1670-1986 Automatic fire detection and alarm systems - System design, installation, and commissioning
AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
AS 2941-1995 Fixed fire protection installations - Pumpset systems
AS 1074-1989 Steel tubes and tubulars for ordinary service (Reconfirmed 2018)
AS 3198-1990 Approval and test specification - Electric cables - XLPE insulated - For working voltages up to and including 0.6/1 kV
AS 1530.4-1990 Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction
AS 2053-1984 Non-metallic conduits and fittings
AS 3187-1986 Approval and test specification - Mineral-insulated metal-sheathed cables
AS 2220.1-1989 Emergency warning and intercommunication systems in buildings - Equipment design and manufacture
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2293.1-1987 Emergency evacuation lighting in buildings - Design and installation
AS 1668.1-1991 The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control
AS 2118-1982 Automatic fire sprinkler systems (known as the SAA Code for Automatic Fire Sprinkler Systems)
AS 2052-1977 Metallic conduits and fittings
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 3116-1990 Approval and test specification - Electric cables - Elastomer insulated - For working voltages up to and including 0.6/1 kV
AS 1660.1-1986 Methods of test for electric cables, cords and conductors - Conductors and metallic components
AS 2692-1986 Busbar trunking systems (busways)

AS/NZS 4507:1998 Cables - Fire performance
AS/NZS 1735.18:2002 Lifts, escalators, and moving walks Passenger lifts for private residence - Automatically controlled
AS 2941-2002 Fixed fire protection installations - Pumpset systems
AS 1735.2-1997 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS/NZS 3009:1998 Electrical installations - Emergency power supplies in hospitals
AS 1735.2-2001 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 2293.1-2005 Emergency escape lighting and exit signs for buildings - System design, installation and operation
AS 1670.4-2004 Fire detection, warning, control and intercom systems - System design, installation and commissioning Sound systems and intercom systems for emergency purposes
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 1668.3-2001 The use of ventilation and airconditioning in buildings Smoke control systems for large single compartments or smoke reservoirs
AS/NZS 2293.1:1998 Emergency evacuation lighting for buildings System design, installation and operation
AS 1670.1-2004 Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire

View more information
$113.50
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more