    Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  11-05-2022

    Language(s):  English

    Published date:  10-03-2002

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 61241.4:2002 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - TYPE OF PROTECTION 'pD'
    4 - PREFACE
    5 - CONTENTS
    7 - 1 Scope
    7 - 2 Normative references
    8 - 3 Definitions
    8 - 3.1 type of protection ‘pD’
    8 - 3.2 overpressure
    9 - 3.3 pressurization
    9 - 3.4 protective gas
    9 - 3.5 enclosure
    9 - 3.6 pressurized enclosure
    9 - 3.7 static pressurization
    9 - 3.8 pressurization with leakage compensation
    9 - 3.9 pressurization with continuous flow of the protective gas
    9 - 3.10 electrical apparatus
    9 - 3.11 ignition-capable apparatus
    10 - 3.12 self-revealing fault
    10 - 3.13 opening
    10 - 3.14 protective device
    10 - 3.15 alarm
    10 - 3.16 indicator
    10 - 3.17 protected apparatus
    10 - 3.18 pressurization system
    10 - 3.19 alternate (or auxiliary) source of supply of protective gas
    10 - 3.20 zones
    10 - 3.21 zone 20
    11 - 3.22 zone 21
    11 - 3.23 zone 22
    11 - 4 Pressurization principle
    11 - 4.1 Protective gas
    11 - 4.2 Automatic disconnection
    11 - 4.3 Cleaning
    11 - 4.4 Discharge of protective gas
    12 - 5 General constructional requirements
    12 - 5.1 Electrical performance of apparatus
    12 - 5.2 Mechanical strength
    12 - 5.3 Apertures
    12 - 5.4 Electrical connections to enclosures
    12 - 5.5 Doors and covers
    13 - 6 Temperature limits
    13 - 7 Safety provisions and safety devices (except for static pressurization)
    13 - 7.1 General
    14 - 7.2 Pressure- or flow-activated devices
    14 - 7.3 Electrical supply
    14 - 7.4 Switching off electrical supply
    14 - 7.5 Failure of pressurization
    14 - 7.5.1 Protection requirements
    16 - 7.6 Level of overpressure
    16 - 7.7 Possible sources of ignition
    16 - 7.8 Enclosed components
    16 - 7.9 Separate enclosures
    16 - 8 Safety provisions and safety devices for static pressurization
    17 - 9 Supply of protective gas
    17 - 9.1 Type of gas
    17 - 9.2 Second source of supply
    17 - 9.3 Temperature
    17 - 10 Verification and tests
    17 - 10.1 General
    18 - 10.2 Type verification and tests
    18 - 10.3 Overpressure test
    18 - 10.4 Minimum overpressure test
    18 - 10.4.1 Test conditions
    18 - 10.4.2 Number of tests
    18 - 10.5 Leakage test
    19 - 10.6 Impact test
    19 - 10.7 Routine tests
    19 - 10.7.1 Overpressure test
    19 - 10.7.2 Leakage test
    19 - 11 Marking
    19 - 11.1 Pressurized enclosure
    19 - 11.2 Additional marking
    20 - 11.3 Pressurized enclosures protected by static pressurization
    20 - 11.4 Any other marking required
    21 - Annex A - Ducts for protective gas supply
    24 - Annex B - Installation requirements for pressurization
    24 - B.1 Source of protective gas
    24 - B.2 Automatic switch-off
    24 - B.3 Manual switch off
    24 - B.4 Common supply of protective gas
    25 - B.5 Switching off electrical supply

    Abstract - (Show below) - (Hide below)

    Specifies the requirements for design, construction, testing and marking of electrical apparatus, with type of protection pressurization 'pD', intended for use in combustible dust atmospheres. This Standard is identical with and has been reproduced from IEC 61241-4:2001.

    Scope - (Show below) - (Hide below)

    This part of IEC 61241, gives requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.This standard contains the specific requirements for construction and testing, including protective requirements that apply to electrical apparatus with type of protection pressurization pD intended for use in potentially combustible dust atmospheres.This standard includes the requirements for the construction of the enclosure and its associated components, including, if any, the inlet and outlet ducts for the protective gas, and for the safety provisions and devices necessary to ensure that pressurization is established and maintained for type of protection pressurization pD.Requirements for pressurized enclosures with an internal source of dust release are not included in this standard.This standard does not cover the requirements for pressurized rooms with or without internal sources of dust release.This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion or to pyrophoric substances.This standard does not cover combined gas and dust hazard. Those requirements are under consideration.The requirements contained in this standard are supplementary to those in IEC 61241.1.1.

    General Product Information - (Show below) - (Hide below)

    Committee EL-014
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS/NZS 61241.4:2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 61241.2.3:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the minimum ignition energy of dust/air mixtures
    AS/NZS 61241.2.1:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Methods for determining the minimum ignition temperature of dust
    AS/NZS 61241.2.2:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the electrical resistivity of dust in layers
    AS/NZS 61241.1.2:2000 Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance
    AS/NZS 61241.1.1:1999 Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus
    AS/NZS 61241.3:1999 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 60079.17:2009 Explosive atmospheres Electrical installations inspection and maintenance (IEC 60079-17, Ed.4.0 (2007) MOD)
    AS/NZS 3800:2012 Electrical equipment for explosive atmospheres - Repair and overhaul
    AS 3846-2005 The handling and transport of dangerous cargoes in port areas
    AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
    AS/NZS 4761.1:2003 Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards
    AS/NZS 4761.2:2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency
    AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
    AS/NZS 3019:2007 Electrical installations - Periodic verification
    AS/NZS 60079.0:2012 Explosive atmospheres Equipment - General requirements
    HB 239:2011 Guidance on the repair and overhaul of electrical equipment for explosive atmospheres
    AS 60204.11-2006 Safety of machinery - Electrical equipment of machines Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c and not exceeding 36 kV (IEC 60204-11, Ed. 1.0 (2000) MOD)
    AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
    AS 60204.1-2005 Safety of machinery - Electrical equipment of machines General requirements (IEC 60204-1, Ed. 5 (FDIS) MOD)
    AS/NZS 4783.2:2002 Performance of electrical lighting equipment - Ballasts for fluorescent lamps Energy labelling and minimum energy performance standards requirements (Reconfirmed 2013)
    HB 13-2007 Electrical equipment for hazardous areas
    AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective
Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more