ASTM D 4012 : 2015 : REDLINE

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Adenosine Triphosphate (ATP) Content of Microorganisms in Water
Available format(s)

PDF

Superseded date

29-09-2023

Language(s)

English

Published date

18-11-2015

CONTAINED IN VOL. 11.02, 2017 Defines a protocol for capturing, extracting and quantifying the cellular adenosine triphosphate (cATP) content associated with microorganisms normally found in laboratory cultures, waters, wastewaters, and in plankton and periphyton samples from waters.

1.1This test method covers a protocol for capturing, extracting and quantifying the cellular adenosine triphosphate (cATP) content associated with microorganisms normally found in laboratory cultures, waters, wastewaters, and in plankton and periphyton samples from waters.

1.2The ATP is measured using a bioluminescence enzyme assay, whereby light is generated in amounts proportional to the concentration of ATP in the samples. The light is produced and measured quantitatively as relative light units (RLU) which are converted by comparison with an ATP standard and computation to pg ATP/mL.

1.3This method does not remove all known chemical interferences, known to either luminesce in the 530 ± 20 nm range, or to quench light emitted in that range. It should not be used to determine ATP concentrations in samples with dissolved organic compounds, heavy metals or >10 000 ppm total dissolved solids. Alternative methods have been developed for determining ATP concentrations in fluids samples likely to contain such interferences (Test Methods D7687 and E2694).

1.4Knowledge of the concentration of ATP can be related to viable biomass or metabolic activity of microorganisms (Appendix X1).

1.5This test method offers a high degree of sensitivity, rapidity, accuracy, and reproducibility.

1.6The analyst should be aware that the precision statement pertains only to determinations in reagent water and not necessarily in the matrix being tested.

1.7This test method is equally suitable for use in the laboratory or field.

1.8The method normally detects cATP concentrations in the range of 0.1 pg cATP/mL (–1.0Log10 [pg cATP/mL]) to 4 000 000 pg cATP/mL (6.6 Log10 [pg cATP/mL]) in 50 mL water samples.

1.9Providing interferences can be overcome, bioluminescence is a reliable and proven method for qualifying and quantifying ATP, although the method does not differentiate between ATP from different sources, for example, from different types of microorganisms, such as bacteria, fungi, algae and protozoa.

1.10The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.11This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 19
DocumentType
Redline
Pages
9
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM E 2694 : 2016 : REDLINE Standard Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids
ASTM D 7687 : 2017 : REDLINE Standard Test Method for Measurement of Cellular Adenosine Triphosphate in Fuel and Fuel-associated Water With Sample Concentration by Filtration
ASTM E 1326 : 2015-07 GUIDE FOR EVALUATING NON-CULTURE MICROBIOLOGICAL TESTS
AWWA M68 : 2017 WATER QUALITY IN DISTRIBUTION SYSTEMS
ASTM D 7847 : 2017 : REDLINE Standard Guide for Interlaboratory Studies for Microbiological Test Methods
ASTM E 645 : 2013 Standard Practice for Evaluation of Microbicides Used in Cooling Water Systems
ASTM D 6469 : 2017 : REDLINE Standard Guide for Microbial Contamination in Fuels and Fuel Systems

ASTM E 2694 : 2016 : REDLINE Standard Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids
ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 7687 : 2017 : REDLINE Standard Test Method for Measurement of Cellular Adenosine Triphosphate in Fuel and Fuel-associated Water With Sample Concentration by Filtration

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more