Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 6160 : 1998 : R2017

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Determination of Polychlorinated Biphenyls (PCBs) in Waste Materials by Gas Chromatography
Available format(s)

Hardcopy , PDF

Superseded date

04-01-2022

Language(s)

English

Published date

10-11-2017

CONTAINED IN VOL. 05.03, 2017 Defines a two-tiered analytical approach to PCB screening and quantitation of liquid and solid wastes, such as oils, sludges, aqueous solutions, and other waste matrices.

1.1This test method2 covers a two-tiered analytical approach to PCB screening and quantitation of liquid and solid wastes, such as oils, sludges, aqueous solutions, and other waste matrices.

1.2Tier I is designed to screen samples rapidly for the presence of PCBs.

1.3Tier II is used to determine the concentration of PCBs, typically in the range of from 2 mg/kg to 50 mg/kg. PCB concentrations greater than 50 mg/kg are determined through analysis of sample dilutions.

1.4This is a pattern recognition approach, which does not take into account individual congeners that might occur, such as in reaction by-products. This test method describes the use of Aroclors3 1016, 1221, 1232, 1242, 1248, 1254, 1260, 1262, and 1268, as reference standards, but others could also be included. Aroclors 1016 and 1242 have similar capillary gas chromatography (GC) patterns. Interferences or weathering are especially problematic with Aroclors 1016, 1232, and 1242 and may make distinction between the three difficult.

1.5This test method provides sample clean up and instrumental conditions necessary for the determination of Aroclors. Gas chromatography (GC) using capillary column separation technique and electron capture detector (ECD) are described. Other detectors, such as atomic emission detector (AED) and mass spectrometry (MS), may be used if sufficient performance (for example, sensitivity) is demonstrated. Further details about the use of GC and ECD are provided in Practices E355, E697, and E1510.

1.6Quantitative results are reported on the dry weights of waste samples.

1.7Quantification limits will vary depending on the type of waste stream being analyzed.

1.8The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
D 02
DocumentType
Test Method
Pages
15
ProductNote
Reconfirmed 2017
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 6074 : 2015 Standard Guide for Characterizing Hydrocarbon Lubricant Base Oils
ASTM D 6823 : 2008 : R2013 Standard Specification for Commercial Boiler Fuels With Used Lubricating Oils

ASTM E 1510 : 1995 : R2013 : EDT 1 Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
ASTM D 4059 : 2000 : R2005 : EDT 1 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography
ASTM D 4059 : 2000 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography
ASTM E 1510 : 1995 : R2000 Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
ASTM D 4059 : 2000 : R2010 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography
ASTM E 288 : 1994 : R1998 Standard Specification for Laboratory Glass Volumetric Flasks
ASTM E 1510 : 1995 : R2005 Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
ASTM E 1510 : 1995 : R2021 Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
ASTM E 355 : 1996 : R2021 : EDT 1 Standard Practice for Gas Chromatography Terms and Relationships
ASTM E 1510 : 1995 Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
ASTM E 203 : 2016 : REDLINE Standard Test Method for Water Using Volumetric Karl Fischer Titration
ASTM E 355 : 1996 : R2014 Standard Practice for Gas Chromatography Terms and Relationships
ASTM D 4059 : 2000 : R2018 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography

View more information
$135.86
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more