We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • ASTM D 6276 : 1999 : REV A : R2006

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    Standard Test Method for Using pH to Estimate the Soil-Lime Proportion Requirement for Soil Stabilization

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  01-07-2015

    Language(s):  English

    Published date:  01-05-2006

    Publisher:  American Society for Testing and Materials

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 04.09, 2015 Covers a means for estimating the soil-lime proportion requirement for stabilization of a soil.

    Scope - (Show below) - (Hide below)

    1.1 This test method provides a means for estimating the soil-lime proportion requirement for stabilization of a soil. This test method is performed on soil passing the 425-m (No. 40) sieve. The optimum soil-lime proportion for soil stabilization is determined by tests of specific characteristics of stabilized soil such as unconfined compressive strength or plasticity index.

    1.2 Some highly alkaline by-products (lime kiln dust, cement kiln dust, and so forth) have been successfully used to stabilize soil. This test method is not intended for these materials and any such product would need to be tested for specific characteristics as indicated in .

    1.3 This test method is used to determine the lowest percentage of lime that results in a soil-lime pH of 12.4.

    1.4 Lime is not an effective stabilizing agent for all soils. Some soil components such as sulfates, phosphates, organics, and so forth can adversely affect soil-lime reactions and may produce erroneous results using this test method.

    This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee D 18
    Document Type Test Method
    Product Note Reconfirmed 2006
    Publisher American Society for Testing and Materials
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 3740 : 2012-06 PRACTICE FOR MINIMUM REQUIREMENTS FOR AGENCIES ENGAGED IN TESTING AND/OR INSPECTION OF SOIL AND ROCK AS USED IN ENGINEERING DESIGN AND CONSTRUCTION
    ASTM E 11 : 2017 : REDLINE Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves
    ASTM D 4753 : 2015 : REDLINE Standard Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction Materials Testing
    ASTM C 977 : 2010 Standard Specification for Quicklime and Hydrated Lime for Soil Stabilization
    ASTM D 653 : 2014 : REDLINE Standard Terminology Relating to Soil, Rock, and Contained Fluids
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective
Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more