Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
Available format(s)

Hardcopy , PDF

Superseded date

19-10-2023

Language(s)

English

Published date

11-02-2020

1.1This test method is used to identify and to measure the emissions of volatile organic compounds (VOCs) emitted from samples of cured spray polyurethane foam (SPF) insulation using micro-scale environmental test chambers combined with specific air sampling and analytical methods for VOCs.

1.2Specimens prepared from product samples are maintained at specified conditions of temperature, humidity, airflow rate, and elapsed time in micro-scale chambers that are described in Practice D7706. Air samples are collected periodically at the chamber exhaust at the flow rate of the micro-scale chambers.

1.2.1Samples for formaldehyde and other low-molecular weight carbonyl compounds are collected on treated silica gel cartridges and are analyzed by high performance liquid chromatography (HPLC) as described in Test Method D5197 and ISO 16000-3.

1.2.2Samples for other VOCs are collected on multi-sorbent samplers and are analyzed by thermal-desorption gas chromatography / mass spectrometry (TD-GC/MS) as described in U.S. EPA Compendium Method TO-17 and ISO 16000-6.

1.3This test method is intended specifically for SPF insulation products. Compatible product types include two component, high pressure and two-component, low pressure formulations of open-cell and closed-cell SPF insulation.

1.4VOCs that can be sampled and analyzed by this test method generally include organic blowing agents such as 1,1,1,3,3-pentafluoropropane, formaldehyde and other carbonyl compounds, residual solvents, and some amine catalysts. Emissions of some organic flame retardants can be measured after 24 h with this method, such as tris (chloroisopropyl) phosphate (TCPP).

1.5This test method does not cover the sampling and analysis of methylene diphenyl diisocyanate (MDI) or other isocyanates.

1.6Area-specific and mass-specific emission rates are quantified at the elapsed times and chamber conditions as specified in 13.2 and 13.3 of this test method.

1.7This test method is used to identify emitted compounds and to estimate their emission factors at specific times. The emission factors are based on specified conditions, therefore, use of the data to predict emissions in other environments may not be appropriate and is beyond the scope of this test method. The results may not be representative of other test conditions or comparable with other test methods.

1.8This test method is primarily intended for freshly applied, SPF insulation samples that are sprayed and packaged as described in Practice D7859. The measurement of emissions during spray application and within the first hour following application is outside of the scope of this test method.

1.9This test method can also be used to measure the emissions from SPF insulation samples that are collected from building sites where the insulation has already been applied. Potential uses of such measurements include investigations of odor complaints after product application. However, the specific details of odor investigations and other indoor air quality (IAQ) investigations are outside of the scope of this test method.

1.10The values stated in SI units are to be regarded as standard. No other units of measure are used.

1.11This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.12This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
D 22
DocumentType
Test Method
Pages
14
ProductNote
ε1NOTE—Editorially added research report information to Section16andAppendix X1in February 2020.
This standard is also refers to 40 CFR Appendix B to Part 136,California Department of Public Health Standard,U.S. EPA Method 325B.
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 8345 : 2021 Standard Test Method for Determination of an Emission Parameter for Phthalate Esters and Other Non-Phthalate Plasticizers from Planar Polyvinyl Chloride Indoor Materials for Use in Mass Transfer Modeling Calculations
ASTM D 8141 : 2022 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
ASTM D 8445 : 2022 : REV A Standard Practice for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation Samples in a Large-scale Ventilated Enclosure
ASTM D 7859 : 2019 Standard Practice for Spraying, Sampling, Packaging, and Test Specimen Preparation of Spray Polyurethane Foam (SPF) Insulation for Testing of Emissions Using Environmental Chambers

ASTM D 5337 : 2023 Standard Practice for Setting and Verifying the Flow Rate of Personal Sampling Pumps
ASTM D 6196 : 2015 : EDT 1 Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air
ASTM D 5337 : 2011 : R2016 Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps
ASTM D 6196 : 2023 Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air
ASTM D 5197 : 2016 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
ASTM D 1356 : 2020 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5197 : 2021 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)

View more information
$135.86
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more