Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM E 1125 : 2016 : REDLINE

Current
Current

The latest, up-to-date edition.

Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum
Available format(s)

PDF

Language(s)

English

Published date

01-07-2016

CONTAINED IN VOL. 12.02, 2018 Specifies procedure used for calibration and characterization of primary terrestrial photovoltaic reference cells to a required reference spectral irradiance distribution.

1.1This test method is intended for calibration and characterization of primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution, such as Tables G173. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of photovoltaic devices.

1.2Primary photovoltaic reference cells are calibrated in natural sunlight using the relative quantum efficiency of the cell, the relative spectral distribution of the sunlight, and a tabulated reference spectral irradiance distribution. Selection of the reference spectral irradiance distribution is left to the user.

1.3This test method requires the use of a pyrheliometer that is calibrated according to Test Method E816, which requires the use of a pyrheliometer that is traceable to the World Radiometric Reference (WRR). Therefore, reference cells calibrated according to this test method are traceable to the WRR.

1.4This test method is used to calibrate primary reference cells; Test Method E1362 may be used to calibrate secondary and non-primary reference cells (these terms are defined in Terminology E772).

1.5This test method applies only to the calibration of a photovoltaic cell that shows a linear dependence of its short-circuit current on irradiance over its intended range of use, as defined in Test Method E1143.

1.6This test method applies only to the calibration of a reference cell fabricated with a single photovoltaic junction.

1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
E 44
DocumentType
Redline
Pages
14
PublisherName
American Society for Testing and Materials
Status
Current

ASTM E 1040 : 2010 Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells
ASTM E 772 : 2015 : REDLINE Standard Terminology of Solar Energy Conversion
ASTM E 2236 : 2010 : R2015 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
ASTM E 2236 : 2010 : R2019 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
ASTM E 973M : 1996 Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell [Metric] (Withdrawn 2005)
ASTM E 948 : 2016 : REDLINE Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight
ASTM E 2236 : 2010 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
08/30188055 DC : DRAFT AUG 2008 BS EN 60904-4 - PHOTOVOLTAIC DEVICES - PART 4: PROCEDURE FOR ESTABLISHING THE TRACEABILITY OF THE CALIBRATION OF REFERENCE SOLAR DEVICES
ASTM E 1036M : 1996 : EDT 2 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells (Withdrawn 2005)
ASTM E 1040 : 2010 : R2016 Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells
ASTM E 1039 : 1999 Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004)

ASTM G 183 : 2015 : REDLINE Standard Practice for Field Use of Pyranometers, Pyrheliometers and UV Radiometers
ASTM E 816 : 2015 : REDLINE Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
ASTM E 772 : 2015 : REDLINE Standard Terminology of Solar Energy Conversion
ASTM G 138 : 2012 : REDLINE Standard Test Method for Calibration of a Spectroradiometer Using a Standard Source of Irradiance
ASTM E 490 : 2000 SOLAR CONSTANT AND ZERO AIR MASS SOLAR SPECTRAL IRRADIANCE TABLES
ASTM E 2554 : 2013-05 PRACTICE FOR ESTIMATING AND MONITORING THE UNCERTAINTY OF TEST RESULTS OF A TEST METHOD USING CONTROL CHART TECHNIQUES
ASTM E 948 : 2016 : REDLINE Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more