ASTM E 2119 : 2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) Devices

Available format(s)

Hardcopy , PDF

Superseded date

17-04-2024

Language(s)

English

Published date

01-03-2016

CONTAINED IN VOL. 04.12, 2016 Covers the collection and documentation of quality control (QC) measurements for determining acceptable levels of instrumental performance when using field-portable energy-dispersive x-ray fluorescence spectrometry devices (XRFs) for the purposes of generating lead classification results from measurements on paint and other coating films within buildings and related structures.

1.1This practice covers the collection and documentation of quality control (QC) measurements for determining acceptable levels of instrumental performance when using field-portable energy-dispersive x-ray fluorescence spectrometry devices (XRFs) for the purposes of generating lead classification results from measurements on paint and other coating films within buildings and related structures.

1.2QC procedures covered in this provisional practice include the performance of calibration checks, substrate bias checks, and specific instructions for documenting the collected data for later use in reporting the results.

1.3No detailed operating instructions are provided because of differences among the various makes and models of suitable instruments. Instead, the analyst is to follow the instructions provided by the manufacturer of the particular XRF device or other relevant sources of information on XRF operation.

1.4This practice contains notes which are explanatory and are not part of the mandatory requirements of this provisional practice.

1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Committee
D 22
DevelopmentNote
Supersedes ASTM PS 95 (12/2001)
DocumentType
Standard Practice
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM E 2115 : 2015 Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of Other Child-Occupied Facilities

ASTM E 1613 : 2012 : REDLINE Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques
ASTM E 1583 : 1993 Practice for Evaluating Laboratories Engaged in the Determination of Lead in Paint, Dust, Airborne Particulates, and Soil Taken From and Around Buildings and Related Structures (Withdrawn 1998)
ASTM E 1645 : 2001 : R2007 Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
ASTM E 1645 : 2016 : REDLINE Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
ASTM E 1613 : 2012 Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques (Withdrawn 2021)
ASTM E 1645 : 1994 Standard Practice for the Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
ASTM E 1729 : 1999 Standard Practice for Field Collection of Dried Paint Samples for Lead Determination by Atomic Spectrometry Techniques
ASTM E 1605 : 2001 : REV B Standard Terminology Relating to Lead in Buildings
ASTM E 1645 : 2016 Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
ASTM E 1645 : 2001 Standard Practice for the Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
ASTM E 1729 : 2004 Standard Practice for Field Collection of Dried Paint Samples for Lead Determination by Atomic Spectrometry Techniques
ASTM E 1605 : 2000 Standard Terminology Relating to Lead in Buildings
ASTM E 1729 : 2016 Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination
ASTM E 1605 : 2018 Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2018 : REV A Standard Terminology Relating to Lead in Buildings
ASTM E 1613 : 1999 Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques
ASTM E 1605 : 2001 : REV A Standard Terminology Relating to Lead in Buildings
ASTM E 1729 : 2005 Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination (Withdrawn 2014)
ASTM E 1605 : 2003 : EDT 1 Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2019 Standard Terminology Relating to Lead in Buildings
ASTM E 1583 : 2017 Standard Practice for Evaluating Laboratories Engaged in Determination of Lead in Paint, Dust, Airborne Particulates, and Soil Taken From and Around Buildings and Related Structures
ASTM E 1605 : 2003 Standard Terminology Relating to Lead in Buildings
ASTM E 1613 : 2004 Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques
ASTM E 1605 : 2018 : REV B Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2004 Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2001 Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2004 : R2012 Standard Terminology Relating to Lead in Buildings
ASTM E 1605 : 2002 Standard Terminology Relating to Lead in Buildings
ASTM E 1645 : 2001 : R2016 : EDT 1 Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more