ASTM E 330/E330M : 2014 : REDLINE

Current
Current

The latest, up-to-date edition.

Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
Available format(s)

PDF

Language(s)

English

Published date

01-01-2014

CONTAINED IN VOL. 04.11, 2015 Defines the determination of the structural performance of exterior windows, doors, skylights, and curtain walls under uniform static air pressure differences, using a test chamber.

1.1This test method describes the determination of the structural performance of exterior windows, doors, skylights, and curtain walls under uniform static air pressure differences, using a test chamber. This test method is applicable to curtain wall assemblies including, but not limited to, metal, glass, masonry, and stone components.2

1.2This test method is intended only for evaluating the structural performance associated with the specified test specimen and not the structural performance of adjacent construction.

1.3The proper use of this test method requires a knowledge of the principles of pressure and deflection measurement.

1.4This test method describes the apparatus and the procedure to be used for applying uniformly distributed test loads to a specimen.

1.4.1Procedure A (see 11.2) shall be used when a load-deflection curve is not required.

1.4.2Procedure B (see 11.3) shall be used when a load-deflection curve is required.

1.5The text of this standard references notes and footnotes which provide explanatory materials. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.6The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

Committee
E 06
DevelopmentNote
Supersedes ASTM E 330. (01/2014)
DocumentType
Redline
Pages
8
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

ASTM F 2247 : 2011 : R2017 Standard Test Method for Metal Doors Used in Blast Resistant Applications (Equivalent Static Load Method)
ASTM E 2099 : 2000 : R2007 Standard Practice for the Specification and Evaluation of Pre-Construction Laboratory Mockups of Exterior Wall Systems
ANSI A250.13 : 2014(R2018) TESTING AND RATING OF SEVERE WINDSTORM RESISTANT COMPONENTS FOR SWINGING DOOR ASSEMBLIES
ASTM E 1233/E1233M : 2014 : REDLINE Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
ASTM E 2570/E2570M : 2007 : R2019 Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
ASTM F 2247:2011 Standard Test Method for Metal Doors Used in Blast Resistant Applications (Equivalent Static Load Method)
ASTM E 2099 : 2000 : R2014 : EDT 1 Standard Practice for the Specification and Evaluation of Pre-Construction Laboratory Mockups of Exterior Wall Systems
FM 4881 : 2017 EVALUATING EXTERIOR WALL SYSTEMS
ASTM E 2099 : 2000 Standard Practice for the Specification and Evaluation of Pre-Construction Laboratory Mockups of Exterior Wall Systems
CSA A440 : 2017 NORTH AMERICAN FENESTRATION STANDARD/SPECIFICATION FOR WINDOWS, DOORS, AND SKYLIGHTS

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASTM E 1233/E1233M : 2014 : REDLINE Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
ASTM E 1996 : 2017 : REDLINE Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
ASTM E 998 : 2012 : REDLINE Standard Test Method for Structural Performance of Glass in Windows, Curtain Walls, and Doors Under the Influence of Uniform Static Loads by Nondestructive Method
ASTM E 1300 : 2016 : REDLINE Standard Practice for Determining Load Resistance of Glass in Buildings
ASCE 7 10 : 2010 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
ASTM E 997 : 2015 : REDLINE Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more