ASTM F 2102 : 2017 : REDLINE

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants
Available format(s)

PDF

Superseded date

13-09-2017

Language(s)

English

Published date

01-09-2017

CONTAINED IN VOL. 13.01, 2017 Specifies a method for the measurement of the relative extent of oxidation present in ultra-high-molecular-weight polyethylene (UHMWPE) intended for use in medical implants.

1.1This guide covers a method for the measurement of the relative extent of oxidation present in HDPE homopolymers and ultra-high-molecular-weight polyethylene (UHMWPE) intended for use in medical implants. The material is analyzed by infrared spectroscopy. The intensity (area) of the carbonyl absorptions (>C=O) centered near 1720 cm-1 is related to the amount of chemically bound oxygen present in the material. Other forms of chemically bound oxygen (C-O-C, C-O-O-C, C-O-H, and so forth) are not captured by this guide.

1.2Although this guide may give the investigator a means to compare the relative extent of carbonyl oxidation present in various UHMWPE samples, it is recognized that other forms of chemically bound oxygen may be important contributors to these materials' characteristics.

1.3The applicability of the infrared method has been demonstrated by many literature reports. This particular method, using the intensity (area) of the C-H absorption centered near 1370 cm-1 to normalize for the sample’s thickness, has been validated by an Interlaboratory Study (ILS) conducted according to Practice E691.

FIG. 1Typical FTIR Spectra of Oxidized UHMWPE, Showing the Definition of an Area-Based Oxidation Index Based on Normalization Using the 1370-cm-1 Peak

Typical FTIR Spectra of Oxidized UHMWPE, Showing the Definition of an Area-Based Oxidation Index Based on Normalization Using the 1370-cm PeakTypical FTIR Spectra of Oxidized UHMWPE, Showing the Definition of an Area-Based Oxidation Index Based on Normalization Using the 1370-cm Peak

FIG. 2FTIR Spectra Showing the Carbonyl Absorption Bands

Note 1:Note that both reagents effectively extracted the lipids (the lipid absorption peak is centered at approximately 1740 cm-1). The tibial insert was fabricated from highly crosslinked and remelted UHMWPE followed by terminal sterilization in EtO gas (Ref. 1).

FTIR Spectra Showing the Carbonyl Absorption Bands FTIR Spectra Showing the Carbonyl Absorption Bands

1.4The following precautionary caveat pertains only to the test method portion, Section 5, of this specification: This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
F 04
DocumentType
Redline
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded

11/30229855 DC : 0 BS ISO 5834-4 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 4: OXIDATION INDEX MEASUREMENT METHOD
ASTM F 561 : 2013 Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids
ASTM F 2565 : 2013 : REDLINE Standard Guide for Extensively Irradiation-Crosslinked Ultra-High Molecular Weight Polyethylene Fabricated Forms for Surgical Implant Applications
ASTM F 2759 : 2011 : REDLINE Standard Guide for Assessment of the Ultra High Molecular Weight Polyethylene (UHMWPE) Used in Orthopedic and Spinal Devices
ASTM F 2977 : 2013 Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants
17/30360587 DC : 0 BS ISO 5834-4 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 4: OXIDATION INDEX MEASUREMENT METHOD
ASTM F 2183 : 2002 Standard Test Method for Small Punch Testing of Ultra-High Molecular Weight Polyethylene Used in Surgical Implants
ASTM F 2183 : 2002 : R2008 Standard Test Method for Small Punch Testing of Ultra-High Molecular Weight Polyethylene Used in Surgical Implants (Withdrawn 2017)
ASTM F 2381 : 2010 : REDLINE Standard Test Method for Evaluating Trans-Vinylene Yield in Irradiated Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants by Infrared Spectroscopy

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more