We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • ATS 5200.055-2008

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    Technical specifications for plumbing and drainage products Plastics fittings - Connectors with flexible intermediate joints for drainage and sewerage applications

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  20-07-2021

    Language(s):  English

    Published date:  20-10-2008

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - ATS 5200.055-2008 TECHNICAL SPECIFICATIONS FOR PLUMBING AND DRAINAGE PRODUCTS - PLASTICS FITTINGS-CONNECTORS WITH...
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 APPLICATION
    6 - 3 REFERENCED DOCUMENTS
    7 - 4 DEFINITIONS
    7 - 4.1 Expander joint
    7 - 4.2 Swivel joint
    7 - 5 MATERIALS
    7 - 5.1 Plastics materials
    7 - 5.1.1 General
    7 - 5.1.2 Unplasticized polyvinyl chloride (PVC-U)
    7 - 5.1.3 Acrylonitrile butadiene styrene (ABS)
    7 - 5.1.4 Acrylonitrile styrene acrylate (ASA)
    8 - 5.1.5 Polypropylene (PP)
    8 - 5.1.6 Polyethylene (PE)
    8 - 5.2 Elastomeric jointing seals
    8 - 5.3 Solvent cement
    8 - 6 MARKING
    8 - 7 PACKAGING
    8 - 8 DESIGN
    8 - 8.1 End connectors
    8 - 8.1.1 Solvent-welded joints
    9 - 8.1.2 Elastomeric seal (rubber ring) joints
    9 - 8.2 Dimensions
    9 - 8.2.1 General
    9 - 8.2.2 Waterway/Clear bore
    9 - 8.3 Freedom from defects
    9 - 8.4 Expander and swivel joints
    9 - 8.4.1 Protection barrier
    9 - 8.4.2 End stop
    10 - 9 PERFORMANCE REQUIREMENTS AND TEST METHODS
    10 - 9.1 Solvent-welded joints (ABS/PVC or ASA/PVC)
    10 - 9.1.1 Joint strength
    10 - 9.1.2 Shear strength
    10 - 9.2 Elastomeric joints-Contact width and pressure
    10 - 9.3 Fitting-Hydrostatic pressure test
    10 - 9.4 Fitting-Liquid infiltration test
    10 - 9.5 Fitting-High temperature stress-relief test (Injection-moulded fittings-PVC/ABS/ASA)
    10 - 10 ‘VOID’
    10 - 11 PRODUCT DOCUMENTATION
    10 - 11.1 Product data
    10 - 11.2 Installation instructions
    12 - APPENDIX A - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS AUSTRALIAN TECHNICAL SPECIFICATION
    12 - A1 SCOPE
    12 - A2 RELEVANCE
    12 - A3 PRODUCT CERTIFICATION
    12 - A4 DEFINITIONS
    12 - A4.1 Sample
    12 - A4.2 Sampling plan
    12 - A4.3 Type test batch
    12 - A4.4 Type testing
    12 - A5 TESTING
    12 - A5.1 Type testing
    13 - A5.2 Batch release testing
    13 - A5.3 Retesting
    15 - APPENDIX B - JOINT SHEAR STRENGTH TEST
    15 - B1 SCOPE
    15 - B2 PRINCIPLE
    15 - B3 APPARATUS
    15 - B4 TEST SPECIMEN PREPARATION
    15 - B5 PREPARATION OF TEST ASSEMBLIES
    17 - B6 PROCEDURE
    17 - B7 CALCULATIONS
    17 - B8 TEST REPORT

    Abstract - (Show below) - (Hide below)

    This Australian Technical Specification sets out requirements for plastics bodied fittings of nominal sizes up to DN 225 with intermediate flexible joints for sewer or drain applications. These fittings are for use above ground or below ground and intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. The design of the fitting is such that it compensates for misalignment or movement that may be encountered in pipeline installations.

    Scope - (Show below) - (Hide below)

    This Australian Technical Specification sets out requirements for plastics bodied fittings of nominal sizes up to DN 225 with intermediate flexible joints for sewer or drain applications. These fittings are for use above ground or below ground and intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. The design of the fitting is such that it compensates for misalignment or movement that may be encountered in pipeline installations.

    General Product Information - (Show below) - (Hide below)

    Committee WS-031
    Document Type Technical Specification
    Publisher Standards Australia
    Status Withdrawn

    History - (Show below) - (Hide below)

    First published as ATS 5200.055-2008.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS 4401:2006 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings - Polyethylene (PE) (Reconfirmed 2017)
    AS/NZS 1462.8:2008 Methods of test for plastics pipes and fittings Method of testing the leaktightness of assemblies (Reconfirmed 2017)
    AS/NZS 2033:2008 Installation of polyethylene pipe systems
    AS/NZS 1462.13:2006 Methods of test for plastics pipes and fittings Method for the determination of elastomeric seal joint contact width and pressure (Reconfirmed 2017)
    AS/NZS 1462.16:2006 Methods of test for plastics pipes and fittings Method for high temperature testing of pipe (Reconfirmed 2017)
    AS/NZS 3500.2:2003 Plumbing and drainage Sanitary plumbing and drainage
    AS/NZS 3500.5:2000 National Plumbing and Drainage - Domestic installations
    AS/NZS 2032:2006 Installation of PVC pipe systems
    AS 1646-2007 Elastomeric seals for waterworks purposes (Reconfirmed 2018)
    AS/NZS 3879:2006 Solvent cements and priming fluids for PVC (PVC-U and PVC-M) and ABS pipes and fittings
    AS/NZS 1462.19:2006 Methods of test for plastics pipes and fittings C-ring test for fracture toughness of PVC pipes (Reconfirmed 2017)
    AS/NZS 1260:2002 PVC-U pipes and fittings for drain, waste and vent application
    AS/NZS 1462.11:1996 Methods of test for PVC pipes and fittings Method for high temperature stress-relief testing of fittings (Reconfirmed 2017)
    AS/NZS 1462.1:2006 Methods of test for plastics pipes and fittings Method for determining the dimensions of pipes and fittings
    AS/NZS 1462.15:1996 Methods of test for PVC pipes and fittings Method for determination of vinyl chloride monomer content (Reconfirmed 2017)
    AS 5200.000-2006 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products (Reconfirmed 2018)
    AS/NZS 1477:2006 PVC pipes and fittings for pressure applications
    AS/NZS 5065:2005 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications (Reconfirmed 2017)
    AS/NZS 1462.14:1996 Methods of test for PVC pipes and fittings Method for determination of the light transmission of pipe (Reconfirmed 2017)
    AS/NZS 1462.10:1998 Methods of test for plastics pipes and fittings Method for hydrostatic pressure testing of fittings and elastomeric seal joints for non-pressure applications (Reconfirmed 2017)
    AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective
Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more