Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 1747-12:1993

Current
Current

The latest, up-to-date edition.

Methods for measurement of air pollution Determination of the mass concentration of ozone in ambient air: chemiluminescence method
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-10-1993

Committees responsible
National foreword
Method
1 Scope
2 Definition
3 Principle
4 Reagents and materials
5 Apparatus
6 Procedure
7 Expression of results
8 Test report
Annexes
A (informative) Typical performance characteristics and
   specifications for the chemiluminescence ozone
   analyser
B (informative) Bibliography
Figures
1 Schematic diagram of a chemiluminescence ozone
   analyser
2 Schematic diagram of a typical ultraviolet
   photometric calibration system

Gives a method for continuous or daily measurement of ozone in the range 2Gmg/m3 to 10 mg/m3.

1.1 General

This International Standard specifies a chemiluminescence method for the determination of the mass concentration of ozone in ambient air.

The method is applicable to the determination of the mass concentration of ozone between 2 µg/m3 [0,001 ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the reference conditions of 25 °C and 101,3 kPa.

Ultraviolet (UV) photometry is specified as the primary calibration method because of its proven accuracy and specificity to ozone. The use of transfer standards is allowed if they have been previously calibrated against the primary calibration method.

1.2 Limitations

The chemiluminescent reaction of ozone with ethylene is not subject to interference from any of the common air pollutants. However, particulate matter, if not removed, will accumulate in the sampling line and may cause a measurable destruction of ozone. If particulate matter is allowed to enter the reaction chamber of the analyser, it will not only scatter the emitted light but will also accumulate on the optical window, thereby causing further attenuation of the emitted light. Also, any nitrogen(II) oxide in the sampled air will to some extent react with the ambient ozone; therefore, the time during which the ambient air remains in the sampling line must be sufficiently short to keep this effect to a minimum.

NOTE 1 It has been reported by some researchers that, at about 80 % relative humidity and 22 °C, the responses for some commercially available chemiluminescence analysers were about 10 % higher than that for dry air. However, comparisons of ambient ozone measurements using commercially available chemiluminescence and UV-photometric analysers showed no significant differences. This suggests that, in practice, any errors associated with calibrations using dry air are compensated by other effects.

Committee
EH/2/3
DevelopmentNote
Supersedes 91/51946 DC. Also numbered as ISO 10313. (06/2005)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Current
Supersedes

ISO 6879:1995 Air quality — Performance characteristics and related concepts for air quality measuring methods

View more information
$247.06
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more