BS 3297-1:1982

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Methods of test
Available format(s)

Hardcopy , PDF

Superseded date

15-12-1995

Language(s)

English

Published date

31-05-1982

Foreword
Cooperating organizations
Methods of test
Section one. General
1. Scope
2. References
3. Definitions
4. Values of voltages
5. Values which characterize a post insulator
6. Marking
Section two. General requirements for tests
7. General requirements for electrical tests
8. Lightning impulse voltage tests
9. Switching impulse voltage tests
10. Power-frequency voltage tests
11. Wet tests
12. Standard atmospheric conditions for tests
13. Correction factors for atmospheric conditions
14. Classification of tests
Section three. Tests in group 1 (type tests)
15. General
16. General requirements for electrical tests in group 1
17. Dry lightning impulse withstand voltage test
18. Dry or wet switching impulse withstand voltage
     test
19. Dry power-frequency withstand voltage test
     (applicable only to post insulators for indoor use)
20. Wet power-frequency withstand voltage test
     (applicable only to post insulators for outdoor use)
21. Tests for mechanical strength
22. Test for deflection under load
Section four. Tests in group II (sample tests)
23. General
24. Verification of dimensions
25. Temperature cycle test
26. Power-frequency puncture test
27. Porosity test (for ceramic post insulators only)
28. Galvanizing test
29. Re-test procedure
Section five. Test in group III (routine tests)
30. General
31. Visual examination
32. Mechanical routine test
33. Thermal shock routine test (for toughened glass
     parts only)
34. Electrical routine test (for type B post insulators
     and for type B units used for composing a type A
     post insulator)
Appendix
A. Methods of testing for tolerances of parallelism,
    eccentricity and angular deviation for post
    insulators
Figures
1. Temperature correction factor alpha for resistivity
    of water as used in wet tests, where p20 and pt
    indicate resistivity at 20 deg C and t deg C
2. Corrections for air density. Exponent m versus
    insulating distance d in metres
3. Humidity corrections for dry lightning impulse and
    dry switching impulse tests Factors k and kh against
    humidity
4. Humidity correction for dry power-frequency voltage
    test. Factor k against absolute humidity (kh = km
    with m given in figure 2)
5. Section through very large insulators indicating the
    greatest thickness phi of the insulator
A.1 Untitled
A.2 Untitled
A.3 Untitled

Specifies tests for post insulators and insulator units for indoor and outdoor service in electrical installations or equipment operating on alternating current with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.

Committee
PEL/36
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS 7354:1990 Code of practice for design of high-voltage open-terminal stations
BS 5463:1977 Specification for a.c. switches of rated voltage above 1 kV
BS 5253:1975 Specification for a.c. disconnectors (isolators) and earthing switches of rated voltage above 1 kV
BS 3297-3:1982 Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Guide to insulator practice
BS 137-1:1982 Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V Methods of test

BS 923-1:1980 Guide on high-voltage testing techniques General
BS 923-2:1980 Guide on high-voltage testing techniques Test procedures
BS 5411-1(1980) : 1980 AMD 8494 METHODS OF TEST FOR METALLIC AND RELATED COATINGS - DEFINITIONS AND CONVENTIONS CONCERNING THE MEASUREMENT OF THICKNESS
BS 3297-2:1982 Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Specification for dimensions

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more