BS 5306-1:1976

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets
Available format(s)

Hardcopy , PDF

Superseded date

31-05-2006

Language(s)

English

Published date

27-02-1976

Foreword
Code of practice
0 Introduction
Section one. General
1 Scope
2 References
3 Definitions
Section two. Provision and siting of hydrants and
               risers
4 Fire hydrants, general
5 Fire hydrants, external
6 Rising mains
7 Landing valves
Section three. Design considerations for hydrants and
               risers
8 General
9 Water supplies and pumping arrangements
10 Identification of fire mains
11 Access for fire appliances
12 Electrical earthing
13 Protection against frost
Section four. Hose reels
14 General considerations
15 Provision and siting
16 Installation of hose reels
17 Co-ordinating spaces for hose reels
18 Water supplies for hose reels
19 Hose reel notices
Section five. Foam inlets
20 General
21 Capability of inlets and lines
22 External connections
23 Delivery pipe
24 Termination of delivery pipe
Section six. Components and materials
25 General conformity with standards
26 Particular requirements
Section seven. Installation
27 Work on site
28 Protection of buildings under construction
29 Temporary notices
Section eight. Initial inspections and acceptance tests
30 Private underground fire hydrants
31 Tests on dry rising mains
32 Tests on wet rising mains
33 Hose reel tests
34 Foam inlet acceptance inspection
35 Indemnities
36 Test records
Section nine. Maintenance of systems and rectification
               of defects
37 Fire hydrants
38 Rising mains
39 Hose reels
40 Rectification of defects
41 Hose reel accessibility
Figures
1 Typical layout of pit for underground fire hydrant
    (brick)
2 Typical layout of pit for underground fire hydrant
    (prefabricated)
3 Typical installation for a hose reel
4 Explanation of dimensions
5 Co-ordinating spaces for fixed hose reels
6 Co-ordinating spaces for swinging arm or recess hose
    reels
Appendices
A Recommendations for protecting installed equipment
    from theft and vandalism
B Matters to be considered relating to the provision
    of fire fighting installations during construction

Provision, siting, installation, system design, water supply and pumping arrangements for hydrants and risers; similarly for hose reels including required co-ordinating spaces, foam inlets generally. Requirements for components and recommendations on installation, inspection, acceptance and maintenance. Advice on fire brigade access.

Committee
FSH/17
DevelopmentNote
To be read in conjunction with BS 5041 & BS 5274(1985). Supersedes BS CP402.101(1952), 72/11960 DC & 86/44774 DC. (08/2005)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
BS 6266:1982 Code of practice for fire protection for electronic data processing installations
BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
I.S. 3216-2:1989 CODE OF PRACTICE FOR THE BULK STORAGE OF LIQUEFIED PETROLEUM GAS
BS 9990:2006 Code of practice for non-automatic fire-fighting systems in buildings
BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
BS 5306-3:1985 Fire extinguishing installations and equipment on premises Code of practice for selection, installation and maintenance of portable fire extinguishers
BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
BS 5041-4:1975 Fire hydrant systems equipment Specification for boxes for landing valves for dry risers
BS 5041-1:1987 Fire hydrant systems equipment Specification for landing valves for wet risers
BS 5588-2:1985 Fire precautions in the design, construction and use of buildings Code of practice for shops
BS PAS 79(2005) : 2005 FIRE RISK ASSESSMENT - GUIDANCE AND A RECOMMENDED METHODOLOGY
04/30104952 DC : DRAFT MARCH 2004 BS 5502-23 - BUILDING AND STRUCTURES FOR AGRICULTURE - PART 23 - FIRE PRECAUTIONS - CODE OF PRACTICE
BS 5041-3:1975 Fire hydrant systems equipment Specification for inlet breechings for dry riser inlets
BS 750:1984 Specification for underground fire hydrants and surface box frames and covers
BS 5502-23:2004 Buildings and structures for agriculture Fire precautions. Code of practice
BS 5306-2:1990 Fire extinguishing installations and equipment on premises Specification for sprinkler systems
BS 5588-5:2004 Fire precautions in the design, construction and use of buildings Access and facilities for fire-fighting
BS 5588-5:1991 Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts
BS 5041-2:1987 Fire hydrant systems equipment Specification for landing valves for dry risers
BS 5454:2000 Recommendations for the storage and exhibition of archival documents
BS 6266:1992 Code of practice for fire protection for electronic data processing installations
BS 5908:1990 Code of practice for fire precautions in the chemical and allied industries
BS 5454:1989 Recommendations for storage and exhibition of archival documents
BS 5502-25:1991 Buildings and structures for agriculture Code of practice for design and installation of services and facilities
BS DD180(1989) : 1989 GUIDE FOR THE ASSESSMENT OF TOXIC HAZARDS IN FIRE IN BUILDINGS AND TRANSPORT
BS 7083:1996 Guide to the accommodation and operating environment for information technology (IT) equipment
BS 5908:1980 Code of practice for fire precautions in chemical plant
BS 5588-5:1986 Fire precautions in the design and construction of buildings. Code of practice for firefighting stairways and lifts
BS 5041-5:1974 Fire hydrant systems equipment Specification for boxes for foam inlets and dry riser inlets
BS 3251:1976 Specification. Indicator plates for fire hydrants and emergency water supplies
BS 5306-0:1986 Fire extinguishing installations and equipment on premises Guide for the selection of installed systems and other fire equipment
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 5588-3:1983 Fire precautions in the design, construction and use of buildings Code of practice for office buildings
BS 5502-23:1990 Buildings and structures for agriculture Code of practice for fire precautions
BS 5306-2:1979 Fire extinguishing installations and equipment on premises Sprinkler systems
BS 5588-12:2004 Fire precautions in the design, construction and use of buildings Managing fire safety
BS 6164:2001 Code of practice for safety in tunnelling in the construction industry

BS 1740:1965 Specification for pipe fittings iron and steel (screwed BSP thread).
BS 1710:1984 Specification for identification of pipelines and services
BS CP99(1972) : LATEST FROST PRECAUTIONS FOR WATER SERVICES
BS 3763:1976 The International System of units (SI)
BS 1212-1:1953 Specification for ballvalves (excluding floats) Piston type
BS 5274:1985 Specification for fire hose reels (water) for fixed installations
BS 5041-3:1975 Fire hydrant systems equipment Specification for inlet breechings for dry riser inlets
BS 5041-1:1987 Fire hydrant systems equipment Specification for landing valves for wet risers
BS 587:1957 Specification. Motor starters and controllers
BS 1387:1985 Specification for screwed and socketed steel tubes and tubulars and for plain end steel tubes suitable for welding or for screwing to BS 21 pipe threads
BS CP402.201(1952) : LATEST SPRINKLER SYSTEMS
BS 5041-5:1974 Fire hydrant systems equipment Specification for boxes for foam inlets and dry riser inlets
BS PD6444-1(1969) : LATEST RECOMMENDATIONS FOR THE COORDINATION OF DIMENSIONS IN BUILDING
BS 5041-4:1975 Fire hydrant systems equipment Specification for boxes for landing valves for dry risers
BS CP1013(1965) : LATEST EARTHING
BS 3169:1981 Specification for first aid reel hoses for fire fighting purposes
BS 3251:1976 Specification. Indicator plates for fire hydrants and emergency water supplies
BS 1212-2:1970 Specification for ballvalves (excluding floats) Diaphragm type (brass body)
BS CP3:CH4-1(1971) : AMD 2708 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - FLATS AND MAISONETTES - (IN BLOCKS OVER TWO STOREYS)
BS 4422-4:1975 Glossary of terms associated with fire Fire protection equipment

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more