Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 5588-5:1991

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts

Available format(s)

Hardcopy , PDF

Superseded date

26-11-2004

Language(s)

English

Published date

30-08-1991

Committees responsible
Foreword
Code of Practice
Section 1. General
1 Scope
2 Definitions
3 Use of this code
Section 2. Planning and construction
4 Firefighting shafts
5 Firefighting stairs
6 Firefighting lobbies
7 Fire mains and landing valves
8 Smoke control
9 Construction of the firefighting shaft
Section 3. Firefighting lift Installation
10 General
11 Firefighting lift cars
12 Firefighting lift wells
13 Firefighting lift machine rooms
14 Firefighting lift control systems
15 Fire service communications systems
Section 4. Electrical services
16 Electrical services
Section 5. Routine inspection and maintenance
17 Routine inspection and maintenance
Appendices
A Resistance to damage of enclosing and separating partitions
B Examples of typical arrangements to keep the firefighting lift
     well free from water
C Operational tests for firefighting lifts
D Model certificate for the commissioning of firefighting lifts
Table
1 Tests for partitions
Figures
0 Height and depth of a building
1 Minimum extent of firefighting stairs and lifts in tall buildings
     and buildings with deep basements
1a Firefighting lift within escape stair
2 Typical firefighting shaft layouts at fire service access level
3 Banks of lifts that incorporate a firefighting lift
4 Examples of protection of the firefighting shaft from external
     fire
5 Deleted
6 Water protection for firefighting lifts
7 Drain outlet to smoke shaft
8 Raised threshold to lift entrance
9 Drainage grid to lift entrance
10 Floor sloped away from lift entrance

Includes details of commissioning tests and routine inspection and maintenance.

Committee
FSH/14
DevelopmentNote
Supersedes BS 5588-5(1986), 89/44633 DC, 97/544071 DC. (07/2002)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 476-23:1987 Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure
BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 5234-2:1992 Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test
BS 5588-9:1989 Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork
BS 8214:1990 Code of practice for fire door assemblies with non-metallic leaves
BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
BS 5655-10:1986 Lifts and service lifts Specification for the testing and inspection of electric and hydraulic lifts
PD 6520:1988 Guide to fire test methods for building materials and elements of construction
BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
BS 476-11:1982 Fire tests on building materials and structures Method for assessing the heat emission from building materials
BS 476-6(1989) : 1989 FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 6: METHOD OF TEST FOR FIRE PROPAGATION FOR PRODUCTS
PD 6512-3:1987 Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to the fire performance of glass
BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
BS 476-20:1987 Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles)
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
BS 476-21:1987 Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction
BS 5306-1:1976 Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets
BS DD197(1990) : 1990 RECOMMENDATIONS FOR VANDAL RESISTANT LIFTS
BS 5588-8:1988 Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people
BS 5839-3:1988 Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment
BS 5395-1:1977 Stairs, ladders and walkways Code of practice for the design of straight stairs
BS 5588-4:1978 Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization
BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
BS 476-31.1:1983 Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions
BS 476-8:1972 Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction
BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction
BS 5588-7:1997 Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more