Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 5654-4:1979

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Stabilized power supplies, d.c. output Tests other than radio-frequency interference

Available format(s)

Hardcopy , PDF

Withdrawn date

20-04-2012

Language(s)

English

Published date

28-02-1979

National foreword
Cooperating organizations
1 General remarks
2 General definitions
3 Instrumentation
4 Conditions of measurement
5 Set of test data
6 Time separation
Section one - Load effect
7 Definition
8 Conditions of measurement
9 Equipment required
10 Set-up and procedure (voltage-stabilized power
     supplies)
11 Set-up and procedure (current-stabilized power
     supplies)
12 Presentation of results
13 Alternates, precautions and error analysis
Section two - Source effect
14 Definition
15 Conditions of measurement
16 Equipment required
17 Set-up and procedure (voltage-stabilized power
     supplies)
18 Set-up and procedure (current-stabilized power
     supplies)
19 Presentation of results
20 Alternates, precautions and error analysis
Section three - Periodic and random deviation
                     (PARD)
21 Definition
22 Conditions of measurement
23 Equipment required
24 Set-up and procedure
25 Alternates, precautions and error analysis
Section four - Drift
26 Definition
27 Conditions of measurement
28 Equipment required
29 Set-up and procedure
30 Alternates, precautions and error analysis
Section five - Output impedance
31 Definition
32 Conditions of measurement
33 Equipment required
34 Set-up and procedure for voltage-stabilized power
     supplies
35 Set-up and procedure for current-stabilized power
     supplies
36 Alternates, precautions and error analysis
Section six - Temperature effect
37 Definition
38 Conditions of measurement
39 Equipment required
40 Set-up and procedure
41 Alternates, precautions and error analysis
Section seven - Transient performance measurement
42 General
43 Scope
44 Conditions of measurement
45 Equipment required
46 Set-up and procedure
47 Alternates, precautions and error analysis
Section eight - Settling effects
48 Definition
49 Conditions of measurement
50 Equipment required
51 Set-up and procedure
52 Alternates, precautions and error analysis
Section nine - Other individual effects
53 General
54 Conditions of measurement
55 Equipment required
56 Set-up and procedure
57 Alternates, precautions and error analysis
Section ten - Combined effects
58 Definition
59 Conditions of measurement
60 Equipment required
61 Set-up and procedure
62 Alternates, precautions and error analysis
Section eleven - Total effect
63 Definition
64 Conditions of measurement
65 Equipment required
66 Set-up and procedure
Section twelve - Measurement of quantities related
                     to the source
67 Definition
68 Conditions of measurement
69 Equipment required
70 Set-up and procedure
71 Alternates, precautions and error analysis
Section thirteen - Capacitance to source terminals
72 Definition
73 Conditions of measurement
74 Equipment required
75 Set-up and procedure
Section fourteen - Capacitance to frame
76 Definition
77 Conditions of measurement
78 Equipment required
79 Set-up and procedure
Section fifteen - Common-mode current
80 Definition
81 Equipment required
82 Set-up and procedure
83 Alternates, precautions and error analysis
Section sixteen - Boundary condition measurements
84 General
85 Threshold measurement
86 Conditions of measurement
87 Equipment required
88 Set-up and procedure for voltage-stabilized power
     supplies
89 Set-up and procedure for current-stabilized power
     supplies
90 Measurement of maximum limited values
91 Measurement of the value of the bounded output
     quantity for the extremity of load
92 Measurement of the peak value of the bounded output
     quantity
Section seventeen - Sound level
93 Definition
94 Conditions of measurement
95 Equipment required
96 Set-up and procedure
97 Calculation of sound level
Section eighteen - Control effects
98 General
99 Conditions of measurement
100 Equipment required
101 Set-up and procedure
Figures

Tests for stabilized power supplies designed to supply d.c. power from an a.c. or d.c. source to laboratories, industrial equipment etc.

Committee
PEL/22
DevelopmentNote
Also numbered as IEC 60478-4 Supersedes 77/28037 DC (08/2005)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Withdrawn

BS 5654-2:1979 Stabilized power supplies, d.c. output Method of specifying rating and performance
BS 6688:1986 Method for specifying requirements for low voltage power supplies, switching type, d.c. output

BS 5654-1:1979 Stabilized power supplies, d.c. output Terms and definitions
BS 4197(1967) : LATEST A PRECISION SOUND LEVEL METER
BS 5148:1975 Method for specifying the performance of stabilized power supply apparatus
BS 5654-2:1979 Stabilized power supplies, d.c. output Method of specifying rating and performance

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more