Specification
Section 1. General
1.1 Scope
1.2 Definitions
Section 2. Ion-selective electrodes
2.1 Performance
2.2 Information to be supplied by the manufacturer
Section 3. Reference electrodes
3.1 Performance
3.2 Information to be supplied by the manufacturer
Section 4. Combination electrodes
4.1 Performance
4.2 Information to be supplied by the manufacturer
Section 5. ISE meters
5.1 Performance and design
5.2 Information to be supplied by the manufacturer
Appendices
A. Outline of procedures for using ion-selective
    electrodes
B. Check tests on electrodes
C. Instrument check tests
D. Standard reference solutions for direct
    potentiometry
E. Bibliographical references
Tables
1. Values of the slope factor k at temperatures from
    0 deg C to 95 deg C
2. Applied voltages for calibrating pX scales
3. Applied voltages for calibrating temperature-
    compensating devices
Figure
1. Calibration curve and determination of practical
    limit of detection

Requirements for performance and other essential characteristics including measuring apparatus. Recommended procedures for determining ions given in Appendix.

This British Standard specifies performance requirements and other requirements for ion-selective electrodes, reference electrodes and combination (dual) ion-selective electrodes in general laboratory use, and for ion-selective electrode meters for laboratory use.

NOTE 1 An outline of procedures used for determining ionic species (except hydrogen ion), and neutral species indirectly, using ion-selective electrodes, is given in Appendix A.

NOTE 2 Recommended tests of performance of electrodes are described in Appendix B.

NOTE 3 Instrument check tests are described in Appendix C.

NOTE 4 Appendix D covers standard reference solutions for direct potentiometry.

NOTE 5 The titles of the publications referred to in this standard are listed on the inside back cover. The numbers in square brackets represent the bibliographical references given in Appendix E.

Committee
W/-
DevelopmentNote
Supersedes 89/51788 DC (09/2005) Reviewed and confirmed by BSI, February 2012. (01/2012)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current

BS 1647-1:1984 pH measurement Specification for pH scale
BS 4743:1979 Specification for safety requirements for electronic measuring apparatus
BS 3145:1978 Specification for laboratory pH meters
BS 2586:1979 Specification for glass and reference electrodes for the measurement of pH
IEC 60173:1964 Colours of the cores of flexible cables and cords
BS 1647-2:1984 pH measurement Specification for reference value standard solutions and operational reference standard solutions

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more