BS EN 12011:1998

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Instrumentation to be used in association with non-active surgical implants. General requirements
Available format(s)

Hardcopy , PDF

Superseded date

31-05-2009

Language(s)

English

Published date

15-05-1998

Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
4 Intended performance
5 Design attributes
6 Materials
7 Design evaluation
8 Manufacture
9 Sterilization
10 Packaging
11 Information supplied by the manufacturer
Annex A (informative) Bibliography
Annex B (informative) A listing of some of the materials
found acceptable for instrument manufacture together with
typical applications
Annex C (informative) Clauses of this European Standard
addressing essential requirements or other provisions of
EU Directives

Defines general requirements for instruments for use in association with non-active surgical implants. Applicable to instruments at the time of manufacture and when they are re-supplied following refurbishment. Applicable to instruments for connection to powered driven systems, but not to the powered driven system itself. Does not apply to instruments associated with dental implants, transendodontic and transradicular implants and ophthalmic implants. Regarding safety, states requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging and information supplied by the manufacturer.

Committee
CH/150
DevelopmentNote
Supersedes 95/561813 DC. (08/2005)
DocumentType
Standard
Pages
14
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
UNE-EN 12011:1998 Identical
NEN EN 12011 : 1998 Identical
I.S. EN 12011:1998 Identical
UNI EN 12011 : 2000 Identical
NBN EN 12011 : 1998 Identical
SN EN 12011 : 1998 Identical
NS EN 12011 : 1ED 1998 Identical
EN 12011 : 1998 Identical
NF EN 12011 : 1998 Identical
DIN EN 12011:1998-03 Identical

EN ISO 14602:2011 Non-active surgical implants - Implants for osteosynthesis - Particular requirements (ISO 14602:2010)
EN 556:1994 + A1:1998 STERILIZATION OF MEDICAL DEVICES - REQUIREMENTS FOR TERMINALLY-STERILIZED MEDICAL DEVICES TO BE LABELLED "STERILE"
ISO 10993-3:2014 Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
EN 550 : 1994 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF ETHYLENE OXIDE STERILIZATION
EN 27740:1992/A1:1997 INSTRUMENTS FOR SURGERY, SCALPELS WITH DETACHABLE BLADES, FITTING DIMENSIONS
EN 30993-4 : 1993 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 4: SELECTION OF TESTS FOR INTERACTIONS WITH BLOOD
EN ISO 10993-11:2009 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006)
EN 1441 : 1997 MEDICAL DEVICES - RISK ANALYSIS
ISO 7151:1988 Surgical instruments Non-cutting, articulated instruments General requirements and test methods
EN 46001 : 1996 QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9001
EN 30993-3 : 1993 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - TESTS FOR GENOTOXICITY, CARCINOGENICITY AND REPRODUCTIVE TOXICITY
EN 540 : 1993 CLINICAL INVESTIGATION OF MEDICAL DEVICES FOR HUMAN SUBJECTS
EN 868-1 : 1997 PACKAGING MATERIALS AND SYSTEMS FOR MEDICAL DEVICES WHICH ARE TO BE STERILIZED - GENERAL REQUIREMENTS AND TEST METHODS
EN 724 : 1994 GUIDANCE ON THE APPLICATION OF EN 29001 AND EN 46001 AND OF EN 29002 AND EN 46002 FOR NON-ACTIVE MEDICAL DEVICES
EN 1174-1 : 1996 STERILIZATION OF MEDICAL DEVICES - ESTIMATION OF THE POPULATION OF MICRO-ORGANISMS ON PRODUCT - REQUIREMENTS
EN 12010 : 1998 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
ISO 4957:1999 Tool steels
ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
ISO 14630:2012 Non-active surgical implants General requirements
EN 30993-6 : 1994 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION
EN 1041:2008+A1:2013 Information supplied by the manufacturer of medical devices
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
ISO 14602:2010 Non-active surgical implants — Implants for osteosynthesis — Particular requirements
EN 552:1994/A2:2000 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY IRRADIATION
ISO 10993-10:2010 Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 10993-12:2012 Biological evaluation of medical devices Part 12: Sample preparation and reference materials
ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
EN 46002 : 1996 QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9002
ISO 7153-1:2016 Surgical instruments Materials Part 1: Metals
ISO 7740:1985 Instruments for surgery Scalpels with detachable blades Fitting dimensions
ISO 10993-9:2009 Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products
EN ISO 10993-12:2012 Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012)
ISO 8319-2:1986 Orthopaedic instruments — Drive connections — Part 2: Screwdrivers for single slot head screws, screws with cruciate slot and cross-recessed head screws
EN 30993-5 : 1994 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - TESTS FOR CYTOTOXICITY - IN VITRO METHODS
EN 60068-2-32:1993 Basic environmental testing procedures - Part 2: Tests - Test Ed: Free fall
EN 980:2008 Symbols for use in the labelling of medical devices
EN ISO 10993-1:2009/AC:2010 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009/COR 1:2010)
ISO 10993-6:2016 Biological evaluation of medical devices Part 6: Tests for local effects after implantation
EN 554 : 1994 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY MOIST HEAT
EN ISO 14630:2012 Non-active surgical implants - General requirements (ISO 14630:2012)
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests

View more information
$247.06
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more