Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 13501-6:2014

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables
Available format(s)

Hardcopy , PDF

Withdrawn date

23-01-2019

Language(s)

English

Published date

31-03-2014

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Classes of reaction to fire performance
5 Test methods
6 Principles for specimen preparation
7 Number of tests for classification
8 Testing of electric cables
9 Classification criteria for electric cables
10 Presentation of classification
11 Field of application of the classification
12 Classification report
Annex A (normative) - Reaction to fire classification report
        for electric cables
Annex B (informative) - Background information as regards
        the reaction to fire performance of cables
Bibliography

Describes the reaction to fire classification procedure for electric cables.

This European Standard provides the reaction to fire classification procedure for electric cables.

NOTE For the purpose of this European Standard the term “electric cables?? covers all power, control and communication cables, including optical fibre cables.

Committee
FSH/21/-/8
DevelopmentNote
Supersedes 12/30252461 DC. (03/2014)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
EN 13501-6:2014 Identical

17/30360475 DC : 0 BS 6701+A1 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - SPECIFICATION FOR INSTALLATION, OPERATION AND MAINTENANCE
BS 8492(2016) : 2016 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
BS 6701(2016) : 2016 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - SPECIFICATION FOR INSTALLATION, OPERATION AND MAINTENANCE
16/30336629 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION

EN 50399 : 2011 AMD 1 2016 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS
PREN 50575 : DRAFT 2012 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
ISO 1716:2010 Reaction to fire tests for products Determination of the gross heat of combustion (calorific value)
ISO 13943:2017 Fire safety — Vocabulary
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 50267-2-3:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
EN ISO 1716:2010 Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010)
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more