Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 14825:2016

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance

Available format(s)

Hardcopy , PDF

Withdrawn date

05-01-2019

Language(s)

English

Published date

31-03-2016

European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols, abbreviated
   terms and units
4 Part load conditions in cooling mode
5 Part load conditions in heating mode
6 Calculation methods for SEER and SEER[on]
7 Calculation methods for seasonal space
   heating efficiency eta[s], SCOP, SCOP[on] and
   SCOP[net]
8 Test methods for testing capacities, EER[bin]
   and COP[bin] values during active mode at
   part load conditions
9 Test methods for electric power input
   during thermostat-off mode, standby mode
   and crankcase heater mode and off mode
10 Test report
11 Technical data sheet
Annex A (normative) - Applicable climate bin hours
        and hours for active mode, thermostatoff,
        standby, off mode and crankcase heater mode
        for air conditioners below and equal to 12 kW
Annex B (normative) - Applicable climate bin hours
        and hours for active, thermostat-off, standby, off
        and crankcase heater modes for space heaters, air
        to water and water/brine to water units, below
        or equal to 400kW
Annex C (normative) - Template for technical data sheet
Annex D (informative) - Adaption of water temperature
         for fixed capacity units
Annex E (informative) - Calculation example for
        SEER[on] and SEER - Application to a
        reversible air-to-air unit with variable capacity
Annex F (informative) - Calculation example for
        SCOP[on] and SCOP[net] - Application to a fixed
        capacity air-to-water heat pump used
        for floor heating
Annex G (informative) - Calculation example for
        SCOP[on] and SCOP[net] Application to a
        fixed capacity brine-to-water heat pump
        used for medium temperature application
Annex H (informative) - Compensation methods
        for air-to-water and water/brine-to-water units
Annex ZA (informative) - Relationship between
         this European Standard and the requirements
         of Commission Regulation (EU) No 206/2012
Annex ZB (informative) - Relationship between
         this European Standard and the requirements
         of Commission Regulation (EU) No 813/2013
         and Commission Delegated Regulation
         (EU) No 811/2013
Bibliography

Gives air conditioners, heat pumps and liquid chilling packages. Also pertains to factory made units defined in EN 14511-1, except single duct, double duct, control cabinet and close control units.

This European Standard covers air conditioners, heat pumps and liquid chilling packages. It applies to factory made units defined in EN 14511-1, except single duct, double duct, control cabinet and close control units.

This European Standard gives the temperatures and part load conditions and the calculation methods for the determination of seasonal energy efficiency SEER and SEERon, seasonal coefficient of performance SCOP, SCOPon and SCOPnet, and seasonal space heating energy efficiency ηs.

Such calculation methods may be based on calculated or measured values.

In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat-off mode, standby mode, off-mode and crankcase heater mode.

NOTE The word \'unit\' is used instead of the full terms of the products.

Committee
RHE/17
DevelopmentNote
Supersedes DD CEN/TS 14825 & 08/30189566 DC. (04/2012) Supersedes 13/30272395 DC. (09/2013) Supersedes 15/30323334 DC. (04/2016)
DocumentType
Standard
Pages
90
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
EN 14825:2018 Identical
EN 14825:2016 Identical

View more information
$615.68
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more