Foreword
1 Scope
2 Normative references
3 Definitions, symbols and designations
   3.1 Terms and definitions
   3.2 Symbols and designation
4 Test equipment
   4.1 Test apparatus
   4.2 Instrumentation
5 Test conditions
6 Test specimen
   6.1 Size
   6.2 Number
   6.3 Design and construction
   6.4 Verification
7 Installation of test specimen
8 Conditioning
   8.1 Moisture content
   8.2 Mechanical conditioning
9 Application of instrumentation
   9.1 Thermocouples
   9.2 Pressure
   9.3 Air flow
10 Test procedure
   10.1 Pre-test procedures
   10.2 Air leakage test
   10.3 Observations
11 Expression of results
   11.1 Ambient temperature only test to satisfy S[a] classification
   11.2 Ambient together with medium temperature tests to satisfy S[m]
12 Test report
13 Field of direct application of test results
   13.1 General
   13.2 Construction of assembly
   13.3 Size and aspect ratio
   13.4 Glazing
   13.5 Hardware and fittings
   13.6 Seals
Annex A (informative) Test principle
Annex B (informative) Test apparatus

Describes a method for determining the leakage of cold and warm smoke from one side of a door assembly to the other under the specified test conditions.

This Part of EN 1634 specifies a method for determining the leakage of cold and warm smoke from one side of a door assembly to the other under the specified test conditions. The test can be applied to door and shutter assemblies of different types intended for purposes of controlling the passage of smoke in case of fire. This test can also be applied to lift landing doors and conveyor system doors and shutters. The principle of the test is explained briefly in annex A.

Committee
FSH/22
DevelopmentNote
Supersedes 96/543041 DC. (09/2002)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
13/30277228 DC : 0 BS 8607 - MECHANICALLY OPERATED PUSH-BUTTON LOCKSETS - REQUIREMENTS AND TEST METHODS
BS PAS 121(2007) : 2007 SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING
BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
BS 8214:2016 Timber-based fire door assemblies. Code of practice
BS 8214:2008 Code of practice for fire door assemblies
BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
12/30263295 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
BS 8607(2014) : 2014 MECHANICALLY OPERATED PUSH BUTTON LOCKSETS - REQUIREMENTS AND TEST METHODS
BS 5516-2:2004 Patent glazing and sloping glazing for buildings Code of practice for sloping glazing
BS 8524-1:2013 Active fire curtain barrier assemblies Specification
09/30189801 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
04/30104952 DC : DRAFT MARCH 2004 BS 5502-23 - BUILDING AND STRUCTURES FOR AGRICULTURE - PART 23 - FIRE PRECAUTIONS - CODE OF PRACTICE
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs
BS 8524-2:2013 Active fire curtain barrier assemblies Code of practice for application, installation and maintenance
16/30332500 DC : 0 BS 8214 - TIMBER-BASED FIRE DOOR ASSEMBLIES - CODE OF PRACTICE
11/30203947 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
PD 7974-3:2003 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3)

ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements

View more information
$294.12
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more