Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 1863-2:2004

Current

Current

The latest, up-to-date edition.

Glass in building. Heat strengthened soda lime silicate glass Evaluation of conformity. Product standard

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

14-10-2004

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 Product description
  4.2 Conformity with the definition of heat strengthened soda
      lime silicate glass
  4.3 Determination of the characteristic's performances
      4.3.1 Characteristics of heat strengthened soda lime
            silicate glass
      4.3.2 Determination of characteristics of heat strengthened
            soda lime silicate glass products
  4.4 Durability
  4.5 Dangerous substances
5 Evaluation of conformity
  5.1 General
  5.2 Initial type testing of the product
      5.2.1 General
      5.2.2 Initial type testing of heat strengthened soda lime
            silicate glass
      5.2.3 Initial type testing of characteristic's performances
  5.3 Factory production control and inspection of samples in
      accordance with a prescribed test plan
  5.4 Initial inspection of factory and of factory production control
  5.5 Continuous surveillance and assessment of the factory production
      control
6 Marking and/or labelling
  6.1 General
  6.2 Product marking
  6.3 Product characteristics
  6.4 'Characteristics/performance identification paper'
Annex A (normative) Factory production control
      A.1 Factory Production Control Requirements
          A.1.1 General
          A.1.2 Organisation
          A.1.3 Control system
      A.2 Marking
      A.3 Inspection and testing tables of heat strengthened
          soda lime silicate glass production
          A.3.1 Information on Table A.1
          A.3.2 Use of proxy testing
Annex B (informative) Tests for factory production control
      B.1 Strength measurement
          B.1.1 Four point bending strength test
          B.1.2 Optical surface pre-stress measurement
      B.2 Fragmentation test
          B.2.1 Requirements
          B.2.2 Test method
Annex C (informative) Provisions for voluntary involvement of
        third party(ies)
Annex ZA (informative) Clauses of this European Standard addressing
         the provisions of EU Construction Products Directive
Bibliography

Describes the evaluation of conformity and the factory production control of flat heat strengthened soda lime silicate glass for use in buildings.

This document covers the evaluation of conformity and the factory production control of flat heat strengthened soda lime silicate glass for use in buildings. Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

Committee
B/520
DevelopmentNote
Supersedes 01/105366 DC (11/2004)
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
NF EN 1863-2 : 2005 Identical
I.S. EN 1863-2:2004 Identical
NS EN 1863-2 : 1ED 2005 Identical
DIN EN 1863-2:2005-01 Identical
UNE-EN 1863-2:2005 Identical
EN 1863-2:2004 Identical
NEN EN 1863-2 : 2004 Identical
NBN EN 1863-2 : 2005 Identical
SN EN 1863-2 : 2004 Identical
UNI EN 1863-2 : 2005 Identical

08/30143158 DC : DRAFT AUG 2008 BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION
BS 6262-7:2017 Glazing for buildings Code of practice for the provision of information
BS 6262-1:2017 Glazing for buildings General methodology for the selection of glazing
BS 7412:2007 Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles
06/30143171 DC : DRAFT SEP 2006 BS 7412 - PLASTICS WINDOWS AND DOORSETS MADE FROM UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) EXTRUDED HOLLOW PROFILES

PREN 13501-5 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS
EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
EN 12758:2011 Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
EN 1096-1:2012 Glass in building - Coated glass - Part 1: Definitions and classification
EN 12898:2001 Glass in building - Determination of the emissivity
EN 1863-1:2011 Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description
EN 13541:2012 Glass in building - Security glazing - Testing and classification of resistance against explosion pressure
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1288-3:2000 Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending)
EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 1063:1999 Glass in building - Security glazing - Testing and classification of resistance against bullet attack
EN 572-4:2012 Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass
EN 357:2004 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance
ISO 9001:2015 Quality management systems — Requirements
EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
EN 356:1999 Glass in building - Security glazing - Testing and classification of resistance against manual attack
EN 572-5:2012 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass
EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass
EN 1096-2:2012 Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more