Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 50306-4:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed

Available format(s)

Hardcopy , PDF

Superseded date

10-04-2020

Language(s)

English

Published date

13-11-2002

Introduction
1 Scope
2 Normative references
3 Multicore cables - sheathed
4 Tests
5 Multicore cables - screened and sheathed
6 Tests
7 Multipair cables - individually screened and
  sheathed and with an overall sheath
8 Tests
Annex A (informative) Guidance on selection of
        cables for type approval
Annex B (informative) Bibliography
Tables

Gives requirements for, and constructions and dimensions of, multicore and multipair cables rated 300 V to earth, of the following types: - unscreened, sheathed for either exposed or protected wiring (0.5 mm[2] to 2.5 mm[2], number of cores from 2 to 48); - screened, sheathed for either exposed or protected wiring (0.5 mm[2] to 2.5 mm[2], number of cores from 2 to 8); - screened, sheathed for either exposed or protected wiring (0.5 mm[2] to 2.5 mm[2], number of pairs of cores from 2 to 7).

EN 50306-4 specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated 300 V to earth, of the following types:

  • unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 48);

  • screened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 8);

  • screened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of pairs of cores from 2 to 7).

NOTE 1 Not all conductor sizes/number of cores are specified for every type.

All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at temperatures of 90 °C or 105 °C dependent upon the sheath system type.

NOTE 2 In EN 50306-4 the higher temperature rating of 105 °C is only allowed where sheath type S2 is used, and where it has been specifically tested for the higher rating (i.e. by long-term thermal endurance testing to demonstrate a lifetime of at least 20 000 h at 125 °C).

The maximum temperature for short-circuit conditions of 160 °C is based on a duration of 5 s.

The cables specified in EN 50306-4 which have a sheath of type EM 101, EM 103 or S2 material are suitable for operation at temperatures as low as – 25 °C and those with sheath of type EM 102 or EM 104 material are suitable for operation at temperatures as low as - 40 °C.

NOTE 3 Where fuel oil is present sheath types EM 101 and EM 102 are not suitable.

NOTE 4 S2 material may also be suitable for operational temperatures as low as –40 °C, but if so must be tested accordingly to confirm this.

Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-1 2).

NOTE 5 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1.

NOTE 6 EN 45545-1 is still under development and should be consulted.

EN 50306-4 should be used in conjunction with EN 50306-1, General requirements,

EN 50306-2, Single core cables, and EN 50306-3, Single core and multicore cables.

Committee
GEL/20/12
DevelopmentNote
Supersedes 01/206812 DC (11/2002)
DocumentType
Standard
ISBN
0580407446
Pages
30
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
DIN EN 50306-4 : 2003 Identical
I.S. EN 50306-4:2002 Identical
NEN EN 50306-4 : 2002 Identical
NF EN 50306-4 : 2003 Identical
NBN EN 50306-4 : 2003 Identical
EN 50306-4:2002 Identical

EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 45545-1 : 2013 COR 2013 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more