Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 50341-2-20:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Overhead electrical lines exceeding AC 45 kV National Normative Aspects (NNA) for ESTONIA (based on EN 50341-1:2012)

Available format(s)

Hardcopy , PDF

Withdrawn date

05-02-2019

Language(s)

English

Published date

31-05-2015

0 Introduction
1 Scope
2 Normative references, definitions and symbols
3 Basis of design
4 Actions on lines
5 Electrical requirements
6 Earthing systems
7 Supports
8 Foundations
9 Conductors and earth-wires
10 Insulators
11 Hardware
12 Quality assurance, checks and taking-over
Annex B (informative) - Conversion of wind
        velocities and ice loads
Annex C (informative) - Application examples of wind
        loads - Special forces
Annex E (normative) - Theoretical method for calculating
        minimum air clearances
Annex F (informative) - Empirical method for calculating
        mid span clearances
Annex G (normative) - Calculation methods for earthing
        systems
Annex H (informative) - Installation and measurements of
        earthing systems
Annex M (informative) - Geotechnical and structural design of
        Foundations

Pertains all new overhead electric lines with nominal system voltages exceeding AC 1 kV and with rated frequencies below 100 Hz.

1.1 General (NCPT) EE.1 Application to new lines This Part2-20 applies to all new overhead electric lines with nominal system voltages exceeding AC 1kV and with rated frequencies below 100Hz. This standard also applies to D.C. overhead lines in structural aspects. (NCPT) EE.2 “New overhead line?? A “new overhead line?? means a completely new line between two points, A and B. A new branch line of the existing power line should be considered as a new power line including the junction support, for which specific requirements should be defined in the Project Specification. 1.2 Field of application (A-dev) EE.1 Application to mounting of telecommunication equipment The Standard EVS‑EN50341:2012 is applicable to fixing of structural elements for telecommunication (antennas, satellite dishes, All Dielectric Self Supporting (ADSS) equipment, etc.), if mounted on power line supports (towers), especially regarding wind forces and ice loads on such fixed elements. The design and installation should be done under the due control of the line owner and/or the competent authority. Mounting of telecommunication equipment on power line supports must be coordinated with line owner and stated in the Project Specification. If telecommunication equipment (antennas, dishes, etc.) will be installed in the transmission line supports, and their size, location or mounting will have major effects on the loads or design of the structures, the requirements of EVS‑EN1993‑3 will also have to be taken into account. If such structures include conductive parts, the requirements on clearances in Section5.8 should be applied. (NCPT) EE.2 Application to existing overhead lines The Standard EVS‑EN50341:2012 shall not be applied to maintenance, reconductoring, tee-offs, extensions or diversions to existing overhead lines in Estonia, unless specifically required in the Project Specification. In cases of major revisions of existing lines the degree of application of the Standard EVS‑EN50341:2012 should be agreed upon by the parties concerned and specified in the Project Specification. (NCPT) EE.3 Application to installations under construction or design Installations in the design and construction stage may be completed by using the standard valid at the beginning of planning unless otherwise agreed with the line owner and/or any other competent authority. It must also be determined in the Project Specification which previous National Standard and to what extent should be applied to the project in question.

Committee
PEL/11
DevelopmentNote
Supersedes BS EN 50423-3 and BS EN 50341-3 which remains current. (05/2015)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
EN 50341-2-20:2015 Identical

EN 14229:2010 Structural timber - Wood poles for overhead lines
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
EN 1997-1:2004/A1:2013 EUROCODE 7: GEOTECHNICAL DESIGN - PART 1: GENERAL RULES
EN 50522:2010 Earthing of power installations exceeding 1 kV a.c.
EN 1991-1-4:2005/A1:2010 EUROCODE 1: ACTIONS ON STRUCTURES - PART 1-4: GENERAL ACTIONS - WIND ACTIONS
EN 61773:1996 Overhead lines - Testing of foundations for structures
EN 61284:1997 Overhead lines - Requirements and tests for fittings

View more information
$541.18
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more