BS EN 50525-3-41:2011

Current
Current

The latest, up-to-date edition.

Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2011

1 Scope
2 Normative references
3 Terms and definitions
4 Heat resistant cables (90 degree C)
Annex A (normative) - Tests for cables to EN 50525-3-41
Annex B (normative) - General data
National Annex (informative) - Origins and identification
               of the particular cable types
Bibliography

Pertains to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire.

EN50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire.

NOTE1 Low emission of smoke is checked in accordance with EN61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see AnnexB of EN50525-1).

The cables are of rated voltages U0/U up to and including 450/750V.

NOTE2 Cables rated 450/750V may be used at 600/1000V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516.

The cables are intended for fixed wiring applications.

The maximum conductor operating temperature for each of the cables in this standard is 90°C.

NOTE3 HD 516 contains extensive guidance on the safe use of cables in this standard.

This EN50525-3-41 should be read in conjunction with EN50525-1, which specifies general requirements.

Committee
GEL/20/17
DevelopmentNote
To be read in conjunction with BS EN 50525-1. Supersedes 08/30188842 DC. (10/2011)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
EN 50525-3-41:2011 Identical

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
12/30248745 DC : 0 BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

EN 50363-5 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
IEC 60228:2004 Conductors of insulated cables
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
EN 50525-1:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

View more information
$294.12
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more