Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60076-1:2011

Current

Current

The latest, up-to-date edition.

Power transformers General

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2012

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Rating and general requirements
6 Requirements for transformers having a tapped winding
7 Connection phase displacement symbols
8 Rating plates
9 Safety, environmental and other requirements
10 Tolerances
11 Tests
12 Electromagnetic compatibility (EMC)
13 High frequency switching transients
Annex A (informative) - Check list of information to be
        provided with enquiry and order
Annex B (informative) - Examples of specifications for
        transformers with tappings
Annex C (informative) - Specification of short-circuit
        impedance by boundaries
Annex D (informative) - Examples of three-phase transformer
        connections
Annex E (normative) - Temperature correction of load loss
Annex F (informative) - Facilities for future fitting of
        condition monitoring systems to transformers
Annex G (informative) - Environmental and safety considerations
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Bibliography

Pertains to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers.

This part of IEC 60076 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers such as:

  • single-phase transformers with rated power less than 1 kVA and three-phase transformers less than 5 kVA;

  • transformers, which have no windings with rated voltage higher than 1 000 V;

  • instrument transformers;

  • traction transformers mounted on rolling stock;

  • starting transformers;

  • testing transformers;

  • welding transformers;

  • explosion-proof and mining transformers;

  • transformers for deep water (submerged) applications.

When IEC standards do not exist for such categories of transformers (in particular transformer having no winding exceeding 1000 V for industrial applications), this part of IEC 60076 may still be applicable either as a whole or in part.

This standard does not address the requirements that would make a transformer suitable for mounting in a position accessible to the general public.

For those categories of power transformers and reactors which have their own IEC standards, this part is applicable only to the extent in which it is specifically called up by cross-reference in the other standard. Such standards exist for:

  • reactors in general (IEC 60076-6);

  • dry-type transformers (IEC 60076-11);

  • self-protected transformers (IEC 60076-13);

  • gas-filled power transformers (IEC 60076-15);

  • transformers for wind turbine applications (IEC 60076-16);

  • traction transformers and traction reactors (IEC 60310);

  • converter transformers for industrial applications (IEC 61378-1);

  • converter transformers for HVDC applications (IEC 61378-2).

At several places in this part it is specified or recommended that an \'agreement\' should be reached concerning alternative or additional technical solutions or procedures. Such agreement is made between the manufacturer and the purchaser. The matters should preferably be raised at an early stage and the agreements included in the contract specification.

Committee
PEL/14
DevelopmentNote
Supersedes BS 171-1(1978) and BS 171-4(1978) (07/2001) Supersedes 01/206406 DC, 90/23125 and 97/204142 DC (07/2002) Supersedes 07/30167951 DC. (11/2011)
DocumentType
Standard
Pages
78
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
DIN EN 60076-1 : 2012 Identical
NF EN 60076-1 : 2012 Identical
I.S. EN 60076-1:2011 Identical
UNE-EN 60076-1:2013 Identical
SN EN 60076-1 : 1997 AMD 12 2002 Identical
IEC 60076-1:2011 Identical
NBN EN 60076-1 : 2011 Identical
EN 60076-1:2011 Identical

BS 6164:2011 Code of practice for health and safety in tunnelling in the construction industry
11/30218915 DC : DRAFT JAN 2011 BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY
BS 6164:2001 Code of practice for safety in tunnelling in the construction industry

IEC 60076-15:2015 Power transformers - Part 15: Gas-filled power transformers
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
EN 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
IEC TR 60616:1978 Terminal and tapping markings for power transformers
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
ISO 3:1973 Preferred numbers Series of preferred numbers
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEC 60068-3-3:1991 Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
IEC 60076-8:1997 Power transformers - Part 8: Application guide
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
EN 60076-10:2016 Power transformers - Part 10: Determination of sound levels
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60050-421:1990 International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 60296:2012 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 60076-6:2007 Power transformers - Part 6: Reactors
IEC 62032:2012 Guide for the Application, Specification and Testing of Phase-Shifting Transformers
ISO 14001:2015 Environmental management systems — Requirements with guidance for use
IEEE C57.142 : 2010 GUIDE TO DESCRIBE THE OCCURRENCE AND MITIGATION OF SWITCHING TRANSIENTS INDUCED BY TRANSFORMERS, SWITCHING DEVICE, AND SYSTEM INTERACTION
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
ISO 9001:2015 Quality management systems — Requirements
ISO 2178:2016 Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method
IEC 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC TS 60076-14:2009 Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials
IEC 60076-13:2006 Power transformers - Part 13: Self-protected liquid-filled transformers
ISO 2409:2013 Paints and varnishes Cross-cut test
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 60721-3-4:1995/A1:1997 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS
IEC 60076-10-1:2016 Power transformers - Part 10-1: Determination of sound levels - Application guide
IEC 60076-16:2011 Power transformers - Part 16: Transformers for wind turbine applications
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
IEC 60310:2016 Railway applications - Traction transformers and inductors on board rolling stock

View more information
$615.68
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more