BS EN 60846-1:2014

Current
Current

The latest, up-to-date edition.

Radiation protection instrumentation. Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation Portable workplace and environmental meters and monitors
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2014

This part of the IEC60846 series applies to dose equivalent (rate) meters and/or monitors for the measurement of ambient dose equivalent (rate) and/or directional dose equivalent (rate) from external beta, X and gamma radiation, as recommended in ICRU, Report 47. NOTE1 If both quantities, ambient dose equivalent and directional dose equivalent are meant, the term dose equivalent may be used as an abbreviation. This part of IEC60846 series applies only to portable meters and monitors which are intended to be used in both the workplace and the environment. It applies to devices that measure the dose equivalent or dose equivalent rate from external beta and/or X and gamma radiation in the dose range between 0,01μSv and 10Sv and the dose rate range between 0,01μSv h −1 and 10Sv h −1 and in the energy ranges given in the following Table. All the energy values are mean energies with respect to the prevailing dose quantity. Table1 Measuring quantities and energy ranges covered by the standard Measuring quantity Energy range for Photon radiation Energy range for Beta-particle radiation H*(10) 12keV to 10MeV - H \'(0,07) 8keV to 250keV 0,07MeV a to 1,2MeV almost equivalent to E max from 225keV to 3,54MeV a For beta-particle radiation, an energy of 0,07MeV is required to penetrate the dead layer of skin of 0,07mm (almost equivalent to 0,07mm of ICRU tissue) nominal depth. NOTE2 Where a dose rate meter or monitor may be attached to a supplementary probe used to monitor contamination, the relevant standard for that probe is IEC60325 . If national legislation requires the use of different measuring quantities, for example, air kerma or exposure, the standard may be used with the respective adjustments. In this document, the expression \'dose equivalent (rate)\' is used when the provisions apply to both the measurement of dose equivalent and the measurement of dose equivalent rate. NOTE3 It does not apply to medical radiology which is within the scope of technical committee 62, where the conditions of radiation exposure may be extremely inhomogeneous, but precisely known. NOTE4 It does not apply to instruments intended to be worn by an individual for the purpose of estimating the radiation dose received by that individual. The object of this standard is to specify the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47. Accordingly, this standard specifies: general characteristics, the functions and performance characteristics of dose equivalent (rate) meters; the methods of test to be used to determine compliance with the requirements of this standard. Some countries may wish to use this type of dose equivalent (rate) meter for measurements in the framework of legal metrology.

Committee
NCE/2
DevelopmentNote
Supersedes BS EN 60846. (10/2014)
DocumentType
Standard
Pages
64
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
EN 60846-1:2014 Identical

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC TR 62461:2015 Radiation protection instrumentation - Determination of uncertainty in measurement
IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
ISO 4037-4:2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields
ISO 6980-3:2006 Nuclear energy — Reference beta-particle radiation — Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence
ISO 6980-2:2004 Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field
EN 60359:2002 Electrical and electronic measurement equipment - Expression of performance
IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 61005:2014 Radiation protection instrumentation - Neutron ambient dose equivalent (rate) meters
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 60086-1:2015 Primary batteries - Part 1: General
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60086-2:2015 Primary batteries - Part 2: Physical and electrical specifications
EN 60086-2:2016 Primary batteries - Part 2: Physical and electrical specifications
ISO 6980-1:2006 Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production
IEC 60086-1:2015 Primary batteries - Part 1: General
ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
EN 61187:1994/corrigendum:1995 ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION
IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
IEC 60325:2002 Radiation protection instrumentation - Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
IEC 60050-393:2003 International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
EN 60068-2-31:2008 ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS

View more information
$568.62
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more